Installation & User Manual

EX07200-121 Rev B
Manufacturer’s National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.
11
BASE MODEL*
FLOW RATE, GPM (LPM)
0.2
(0.76)
0.25
(0.95)
0.3
(1.14)
0.4
(1.51)
0.5
(1.89)
0.7
(2.65)
0.8
(3.03)
1
(3.79)
TEMPERATURE RISE, °F (°C)
SPEX1812
61
(34)
49
(27)
41
(23)
31
(17)
25
(14)
18
(10)
15
(8)
12
(7)
SPEX2412
82
(46)
66
(37)
55
(31)
41
(23)
33
(18)
23
(13)
20
(11)
16
(9)
SPEX3012
-
-
82
(46)
68
(38)
51
(28)
41
(23)
29
(16)
26
(14)
20
(11)
SPEX3512
-
-
-
-
80
(44)
60
(33)
48
(27)
34
(19)
30
(17)
24
(13)
SPEX35
-
-
-
-
80
(44)
60
(33)
48
(27)
34
(19)
30
(17)
24
(13)
SPEX48
-
-
-
-
-
-
82
(46)
66
(37)
47
(26)
41
(23)
33
(18)
SPEX55
-
-
-
-
-
-
-
-
75
(42)
54
(30)
47
(26)
38
(21)
SPEX65
-
-
-
-
-
-
-
-
-
-
63
(35)
55
(31)
44
(24)
SPEX75
-
-
-
-
-
-
-
-
-
-
73
(41)
64
(36)
51
(28)
SPEX95
-
-
-
-
-
-
-
-
-
-
-
-
81
(45)
65
(36)
SPEX3208
-
-
82
(46)
68
(38)
51
(28)
41
(23)
29
(16)
26
(14)
20
(11)
SPEX4208
-
-
-
-
-
-
70
(39)
56
(31)
40
(22)
35
(19)
28
(16)
SPEX8208
-
-
-
-
-
-
-
-
-
-
81
(45)
71
(39)
57
(32)
SPEX3277
-
-
82
(46)
68
(38)
51
(28)
41
(23)
29
(16)
26
(14)
20
(11)
SPEX4277
-
-
-
-
-
-
70
(39)
56
(31)
40
(22)
35
(19)
28
(16)
SPEX60
-
-
-
-
-
-
-
-
82
(46)
59
(33)
51
(28)
41
(23)
SPEX80
-
-
-
-
-
-
-
-
-
-
78
(43)
68
(38)
55
(31)
SPEX90
-
-
-
-
-
-
-
-
-
-
-
-
77
(43)
61
(34)
SPEX100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
68
(38)
6. LAVADVANTAGE UNIT OPERATION
Factory temperature setpoints/maximum adjustable range:
Suffix
Default
Setpoint
(°F)
Minimum
Setpoint
(°F)
Maximum
Setpoint
(°F)
Base Model
<4kW
105
70
140
>4kW
120
S (Sanitation)
120
70
180
ML (Multi-Lavatory)
110
70
110
EE (Emergency Eyewash)
90
70
90
CHANGING SETPOINT TEMPERATURE
To INCREASE temperature, tap the “+” button repeatedly, or hold the “+” down to INCREASE the temperature quickly. To DECREASE
temperature, tap the “–” button repeatedly, or hold the “–” down to DECREASE the temperature quickly.
ADVANCED FUNCTIONS
With the display showing the current setpoint temperature, press BOTH “+” AND “–“ buttons simultaneously for 3 seconds.
Screen Info
Title
Units
Description
Flow Rate
FLO
GPM or LPM
Current water flow rate through unit
Inlet temperature
IN
°F or °C
Cold water temperature
Outlet temperature
OUT
°F or °C
Hot water temperature
Power Factor
PF
%
How hard the heater is working
Software Revision
SR
-
For Technical Support assistance
Hold -to display the current screen title.
Press “+” to advance to the next screen.
Holding both “+” and “–“ at any time for 3 seconds returns the display to the temperature set point, or just let the heater return to
set point display on its own after a period of time.
Note: the values shown above are only for comparison purposes.
*Special suffixed models (i.e. CA, etc.), will have identical temperature rises as their base model
-“Flow rate below turn on flow for this model