7. TROUBLESHOOTING
ENSURE POWER TO THE UNIT IS “OFF” BEFORE REMOVING THE PROTECTIVE COVER FOR ANY REASON.
For status resolution, please consult the table for your heater model below.
LAVADVANTAGE & ACCUMIX II
Code
Name
Possible causes
Heater response
Possible solutions
F23
No heat
- element failure
- ECO tripped/malfunctioning
- triac(s) failed open
- relay/contactor malfunctioning
- control board failure
- inlet water supply out of spec
Heating will be disabled after 30
seconds of continuous no heat
condition.
- measure element resistance with
the unit completely turned off
F24
Low heat
- undervoltage
- triac(s) failed open
- control board failure
- inlet/outlet thermistor(s) failure
Heating enabled, reduced
performance (lower outlet
temperature).
- verify power supply (voltage) while
heater is running
F33
Residual heat
- internal water temperature elevated
without flow
- both triacs failed closed
Heating disabled until outlet
temperature falls below the
reactivation temperature (see
default parameters table).
- run water through the unit
F34
Overvoltage
- inlet voltage is too high compared to
the stated heater specifications
Heating enabled, reduced
performance (higher outlet
temperature).
- have certified personnel verify the
inlet voltage
- provide voltage within specified
range
F36
Undervoltage
- inlet voltage is too low compared to the
stated heater specifications
Heating enabled, reduced
performance (lower outlet
temperature).
- have certified personnel verify the
inlet voltage
- provide voltage within specified
range
F38
High flow
- flow is too high to heat the water to
setpoint temperature
Heating enabled, unit operates as
intended (lower outlet temperature
possible).
- reduce flow (outlet flow restrictor,
faucet aerator)
F47
Inlet thermistor
failure
- inlet thermistor interrupted or
disconnected
Heating enabled based on default
inlet temperature setting (see
default parameters table;
higher/lower outlet temperature
possible).
- inspect connections/wiring of inlet
thermistor
F48
Outlet
thermistor
failure
- outlet thermistor interrupted or
disconnected
Heating enabled, auto calibration
disabled.
- inspect connections/wiring of
outlet thermistor
F64
Freeze warning
- inlet temperature is too low (below
35°F)
Heating disabled while condition is
present.
- increase inlet water temperature
above 35°F
Status code
Model suffix
Default values
F33
T, ML
Trip
170°F
Reactivation
140°F
EE
Trip
100°F
Reactivation
95°F
S
Trip
195°F
Reactivation
165°F
FLOWCO
LED Pattern
Status/Problem
Possible causes
Heater response
Possible solutions
Solid light
Heating
N/A
N/A
N/A
One flash every four
seconds
Idle
N/A
- unit waits for flow
N/A
LAVADVANTAGE & ACCUMIX II DEFAULT PARAMETERS