Product Manual

3
(CANADIAN INSTALLATIONS ONLY) CONNECT ONLY TO A CIRCUIT PROTECTED BY A
CLASS A GROUND FAULT CIRCUIT INTERRUPTER. ATTENTION: BRANCHER UNIQUEMENT
À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR DE FUITE DE TERRE DE CLASSE A.
(CANADIAN INSTALLATIONS ONLY) DO NOT INSTALL IN A BATH ENCLOSURE OR
SHOWER STALL OR CONNECT TO A SALT-REGENERATED WATER SOFTENER OR A
WATER SUPPLY OF SALT WATER. ATTENTION: NE PAS INSTALLER DANS UNE BAIGNOIRE OU UNE CABINE DE
DOUCHE ET NE PAS BRANCHER À UN ADOUCISSEUR D’EAU RÉGÉNÉRÉ AVEC DU SEL OU À UN
APPROVISIONNEMENT EN EAU SALÉE.
(CANADIAN INSTALLATIONS ONLY) USE COPPER CONDUCTORS ONLY. USE BONDING
CONDUCTOR IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE PART I. UTILISEZ
DEZ CONDUCTEURS EN CUIVE UNIQUEMENT. UTILISEZ DES CONDUCTEURS DE MIZE À LA MASSE
CONFORMEMENT AU CODE CANADIEN DE L’ÉLECTRICITÉ, PARTIE I.
SAVE THESE INSTRUCTIONS
GENERAL
The Eemax “LavAdvantageheaters will provide optimum performance and energy savings when located under
the sink and as close as possible to the point of hot water use. For best performance, the heater should be
BELOW the point of use. Failure to do so may void the warranty. Contact your Eemax representative for further
information.
LavAdvantageheaters accept cold or preheated water and heat it to temperatures suitable for normal
domestic usage up to maximum of 140°F. With the “S” option, they can be used as a temperature booster for
sanitation applications up to maximum 180°F. Units built with the “ML” option are factory-set to a maximum
temperature of 110°F (range 80°F - 110°F) and are recommended for hand washing applications. The “ML”
option is an excellent choice for supplying hot water to sensor-type or metering faucets.