Datasheet

07.08.13
07.08.13
BT
BT
RoHS
compliant
LSA Disconnection Module
2/10 10pairs
Art.-No:
46005.1;46005.1F;46005.1R
46005.1x
Mechanical data for plastic insulated copper wire
• Conductor diameter: 0.40 to 0.80 mm
• Outer diameter: 0.68 to 1.60 mm; AWG 26 to 20
Mechanical data for LSA contacts
• Contact can be connected with 2 conductors (same diameter) 0.50 to 0.65 mm
• Durability ≥ 50 cycles, with 2 conductors max. 20 cycles
• Contact material: special brass, silver-plated in contact area ≥ 5 μm
Mechanical data enclosure
• Material: self-extinguishing polyester PBT
• Flammability: UL94 V-0
Electrical data
• Isolation-resistance: > 5 x 104 MΩ
• Contact resistance: < 1 mΩ
• AC-Voltage: 2 kV
eff
• Impulse withstand voltage (wave form 8/20 μs): 3.6 kV
• Allowed ampacity:
LSA contact: equivalent to the ampacity of the connected conductor
LSA connection module - conductor diameter ≥ 0.6 mm: 10 kA
Climatical data
Application in dry or humid rooms without condensation
• Temperature range: -40°C up to +90°C while storage
-20°C up to +80°C while operation
LSA Disconnection Module 2/10 10pairs
Art.-No. Type
46005.1
without colour code
46005.1F
with colour code
46005.1R
red housing for re warning applications
• For LSA backmount frames/channels
• With large wire routing eyes, printed with numbers 1..0
• Cable and routing side can be separeted by disconnection plug

Summary of content (1 pages)