Section 8 - Setting Units at Static Starter Sills
1. If the starter sill was properly installed and the unit is square and is setting hard on the starter sill, the unit will be at the proper elevation and will be level and
plumb from side to side.
2. Compare the jamb unit to established bench marks and move the unit side to side to position it laterally to the final required location.
3. Adjust the unit for plumb, parallel to the plane of the wall, by sliding the slab anchor forward or backward until the unit is plumb. See Figure 70.
4. Rotate the serrated washers where the serrations align with the serrations in the anchor and secure the slab anchor’s anchor bolts.
5. Match drill the slab anchors through the hook anchors on both sides of the unit, and install the pinning screw to lock the frame unit into the final position. See
Figure 71.
Figure 70
Hook Anchor
Figure 71
Jamb Unit
Once the units are set and final
adjustments are made, turn the
washer so that the serrations
align and secure anchor bolts.
17D3 Serrated
Washers
17D4 Slab
Anchor
17D4 Slab
Anchor
Hook Anchor
Turn the serrated washer (17D3)
so that the teeth don't interlock
to simplify anchor adjustments.
Wind Load Anchor
Once final adjustments have been
made, match drill the hook anchor
and install the pin screw to lock the
lateral position of the frame unit.