EFCO 2009 Page 68
Series 8700 / 8800 Unitized Curtain Wall Installation Instructions
Section 15 - Deglaze / Re-glaze Procedures - SSG System
Figure 149
f. When the structural silicone joints are fully cured, remove the temporary retainers. Properly clean and prepare the joints, apply backer rod and the
weather seal. Tool the joint to form an hour glass shaped sealant joint as shown.
Figure 150
Remove temporary
retainers , insert backer
rod, and apply weather
seals, and tool as shown.
Remove temporary
retainers , insert backer
rod, and apply weather
seals, and tool as shown.
Remove temporary
retainers , insert backer
rod, and apply weather
seals, and tool as shown.