3.4.4 External control
You can control the EFOY COMFORT fuel cell externally using a switching
contact, e.g. a solar charger. To do this, the "External control" operating
mode must be enabled.
External control is switched on if an open padlock is displayed at the bot-
tom right of the display.
Switching on external control
1. Press on the operating panel, or select
"Operating mode" in the main menu. The op-
erating mode selection appears.
2. Select the
"External control on" operating mode.
3. Press [ok] to confirm your selection.
An open padlock is displayed at the bottom right of
the display. The EFOY COMFORT is ready to receive
a signal for external control.
If the controller receives an external signal, "RC"
(Remote Control) is displayed
at the bottom right of the display.
INFO:
If you have not enabled external control, a
closed padlock is displayed at the bottom
right of the display when an external signal
is being received.
INFO:
Please contact your specialist dealer for information on using the exter-