User's Manual

PICS POC User’s Manual 13 January 2003
PORT NUMBER
This specifies the port number that
the Reader will accept socket
connections on. It is currently hard
coded in the PICS Manager software
to 50000.
PORT ID
This is the Com Port that is used by
the Access Control System interface.
It should always be set to 0.
BAUD RATE
Specifies the baud rate for the
Access Control System interface. Set
it according to the Access Control
System requirements.
PARITY
Specifies the parity for the Access
Control System interface. Set it
according to the Access Control
System requirements. Valid values
are:
0x0100 NONE
0x0200 ODD
0x0400 EVEN
0x0800 MARK
0x1000 SPACE
DATA BITS
Specifies the data bits for the Access
Control System interface. Set it
according to the Access Control
System requirements. Valid values
are 5, 6, 7, and 8.
REPORTING
STOP BITS
Specifies the baud rate for the
Access Control System interface. Set
it according to the Access Control
System requirements. Valid values
are 1 and 2.
The fields that are shown in bold are fields which the maintainer may have to adjust as
part of the installation, or if the system configuration is changed. It is recommended that
a copy of the current reader.ini file be stored somewhere safe. This copy can be used as a
template for making a new file should changes be required.
17