MSDS

and is expected to exhibit Dermal Corrosivity/Irritation.
Serious Eye Damage/Irritation: The electrolyte contained within the cell or battery is classified as a
corrosive liquid and is expected to exhibit serious Damage/Corrosivity.
Respiratory or Skin Sensitization: The electrolyte contained within the cell or battery is not expected to be a
skin sensitizer according to OECD test 406, based on the available data and the known hazards of the
components. The electrolyte contained within the battery is not expected to be a respiratory tract sensitizer,
based on the available data and the known hazards of the components.
Germ Cell Mutagenicity: The electrolyte contained within the cell or battery is not expected to be mutagenic
according to test such as OECD tests 471, 475, 476, 478 and 479, based on the available data and the known
hazards of the components.
Carcinogenicity: The electrolyte contained within the cell or battery is not expected to be a carcinogen. The
cathode contains Cobalt and Nickel components. These components are classified as IARC 2B possibly
carcinogenic to humans, however they do not pose a threat when contained in the cell or battery sealed unit.
Reproductive Toxicity: The electrolyte contained within the cell or battery is not expected to be a
reproductive hazard according to test such as OECD tests 414 and 421, based on the available data and the
known hazards of the components.
Specific Target Organ Toxicity (STOT) Single Exposure: The electrolyte contained within the cell or
battery is corrosive and is expect to cause respiratory irritation by inhalation. Inhalation of vapors may lead to
severe irritation of the mouth and upper respiratory tract with a burning sensation, pain, burns and
inflammation in the nose and throat; there may also be coughing or difficulty breathing.
Specific Target Organ Toxicity (STOT) Repeated Exposure: The cells or batteries are not expected to
cause organ damage from prolonged or repeated exposure according to tests such as OECD tests 410 and
412, based on the available data and the known hazards of the components.
Aspiration Hazard: The cells or batteries are not classified as an aspiration hazard, based on the available
data and the known hazards of the components. However, due to the corrosive nature of the product if
swallowed, do NOT induce vomiting. If vomiting has occurred after ingestion the person should be observed
to ensure that aspiration into the lungs has not occurred and assessed for chemical burns to the
gastrointestinal and respiratory tracts.
12. ECOLOGICAL INFORMATION
Further information
Ecological injuries are not known or expected under normal use. Do not flush into surface water or sanitary
sewer system.
13. DISPOSAL CONSIDERATION
Advice on disposal
For recycling consult manufacturer.
Contaminated packaging
Disposal in accordance with local regulations
14. TRANSPORT INFORMATION
UN Number: UN 3481