SAFETY DATA SHEET Issuing Date No data available Revision Date 06-May-2015 Revision Number 3 _____________________________________________________________________________________________ The supplier identified below generated this SDS using the UL SDS template. UL did not test, certify, or approve the substance described in this SDS, and all information in this SDS was provided by the supplier or was reproduced from publically available regulatory data sources.
Revision Date 06-May-2015 1237912 - 56V Battery 2.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ Eye contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area. Remove contact lenses, if present and easy to do. Continue rinsing. Seek immediate medical attention/advice.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable extinguishing media CAUTION: Use of water spray when fighting fire may be inefficient. Specific hazards arising from the chemical Product is or contains a sensitizer.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ 7. HANDLING AND STORAGE Precautions for safe handling Handling In case of rupture: Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. In case of insufficient ventilation, wear suitable respiratory equipment. Use only with adequate ventilation and in closed systems.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ Individual protection measures, such as personal protective equipment Eye/face protection Face protection shield. Skin and body protection Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant apron. Impervious gloves.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ 10. STABILITY AND REACTIVITY Reactivity No data available. Chemical stability Stable under recommended storage conditions. Possibility of Hazardous Reactions None under normal processing. Conditions to avoid Exposure to air or moisture over prolonged periods. Incompatible materials Acids. Bases. Oxidizing agent.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ Information on toxicological effects Symptoms Itching. Rashes. Hives. Erythema (skin redness). Burning. May cause blindness. Coughing and/ or wheezing. Delayed and immediate effects as well as chronic effects from short and long-term exposure Sensitization May cause sensitization of susceptible persons. May cause sensitization by skin contact.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ ATEmix (dermal) 1,214.00 mg/kg (ATE) 12. ECOLOGICAL INFORMATION Ecotoxicity Very toxic to aquatic life with long lasting effects. Harmful to aquatic life. Chemical Name Nickel oxide 1313-99-1 Copper 7440-50-8 Toxicity to Algae Toxicity to Fish 72h EC50: > 127.3 mg/L 96h LC50: > 100 mg/L (Pseudokirchneriella (Brachydanio rerio) subcapitata) 96h EC50: 0.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ 13. DISPOSAL CONSIDERATIONS Waste treatment methods Disposal methods This material, as supplied, is not a hazardous waste according to Federal regulations (40 CFR 261).
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ MEX UN-No. Proper Shipping Name Hazard Class Packing Group Description UN3480 LITHIUM ION BATTERIES 9 II UN3480, LITHIUM ION BATTERIES, 9, II ICAO UN-No. Proper Shipping Name Hazard Class Packing Group Description UN3480 LITHIUM ION BATTERIES 9 II UN3480, LITHIUM ION BATTERIES, 9, II IATA UN-No.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ 15. REGULATORY INFORMATION International Inventories TSCA DSL Complies All components are listed either on the DSL or NDSL.
Revision Date 06-May-2015 1237912 - 56V Battery 2.5AH _____________________________________________________________________________________________ .
FICHE DE DONNÉES DE SÉCURITÉ Date de révision 06-mai-2015 Date d'émission Pas de données disponibles Numéro de révision 3 _____________________________________________________________________________________________ Le fournisseur identifié ci-dessous ont généré cette SDS en utilisant le modèle UL SDS.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ PEAU SI (ou les cheveux): Enlever / Enlever immédiatement les vêtements contaminés tout.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ Lentilles de contact Rincer immédiatement et abondamment avec de l'eau, y compris sous les paupières, pendant au moins 15 minutes. Gardez l'œil ouvert pendant le rinçage. Ne pas frotter les zones touchées. lentilles de contact Retirer, si elle est présente et facile à faire. Continuer à rincer. Consulter un / des conseils médicaux immédiats.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ 5. MESURES DE LUTTE CONTRE L'INCENDIE Moyen d'extinction approprié Utiliser des moyens d'extinction appropriés aux conditions locales et l'environnement. Moyens d'extinction déconseillés ATTENTION: L'utilisation de l'eau pulvérisée quand peut-être inefficace lutte contre l'incendie.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ 7. MANIPULATION ET STOCKAGE Précautions à prendre pour une manipulation sans danger En cas de rupture: A manipuler conformément aux normes d'hygiène industrielle et aux consignes de sécurité. Éviter tout contact avec la Manipulation peau, les yeux ou les vêtements. En cas de ventilation insuffisante, porter un appareil respiratoire approprié.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ Mesures de protection individuelle, tels que les équipements de protection individuelle Protection des yeux / du visage l'écran de protection du visage. Protection de la peau et le corps Porter des gants de protection et des vêtements de protection. Vêtements à manches longues. Tablier résistant aux produits chimiques. Gants imperméables.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ 10. STABILITÉ ET RÉACTIVITÉ Réactivité Pas de données disponibles. Stabilité chimique Stable dans les conditions recommandées de stockage. Possibilité de réactions dangereuses Aucun dans des conditions normales. Conditions à éviter Exposition à l'air ou à l'humidité pendant des périodes prolongées. matières incompatibles Acides. Bases.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ Informations sur les effets toxicologiques Symptômes Démangeaisons. Éruptions cutanées transitoires. Urticaire. Érythèmes (rougeurs de la peau). Brûlant. Peut provoquer la cécité. Toux et / ou sifflements.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ ATEmix (dermique) 1,214.00 mg / kg (ATE) 12. INFORMATIONS ÉCOLOGIQUES écotoxicité Très toxique pour la vie aquatique avec effets à long terme. Nocif pour les organismes aquatiques.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ 13. ÉLIMINATION Méthodes de traitement des déchets Méthodes d'élimination Ce matériau, tel que fourni, n'est pas un déchet dangereux selon les règlements fédéraux (40 CFR 261).
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ MEX No ONU. UN3480 Nom d'expédition BATTERIES LITHIUM-ION Classe de danger 9 Groupe d'emballage II La description UN3480, LITHIUM ION, 9, II OACI No ONU. UN3480 Nom d'expédition BATTERIES LITHIUM-ION Classe de danger 9 Groupe d'emballage II La description UN3480, LITHIUM ION, 9, II IATA No ONU.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ 15. INFORMATIONS RÉGLEMENTAIRES Stocks internationaux TSCA DSL conforme Tous les composants sont répertoriés soit sur la LIS ou.
Date de révision 06-mai-2015 1237912 - Batterie 56V 2.5AH _____________________________________________________________________________________________ .