Datasheet

P
RODUCT
S
PECIFICATION
N1hxSW3 18W PS EuPII
Page
15/21
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
S. Trethan 09 08 12 A
5 EMC
The units meet the following EMC requirements:
5.1 Emission with representative device:
Test passed according to EN55022 Class B and FCC15 Class B.
5.2 Immunity To Flicker
Test according to EN 61000-3-2
5.3 Immunity to Fast Transients (Burst)
Test according to EN61000-4-4
Input Line: 2.0kV – 5/50 ns – 5.0 kHz
Output Line: 2.0kV – 5/50 ns – 5.0 kHz
5.4 Immunity to Radiated Electromagnetic Field
Test according to EN 61000-4-3
Test characteristic: 80 – 1000 MHz; 80% AM (1kHz), 3V/m
5.5 Immunity to Electrostatic Discharge
Test according to EN 61000-4-2
Test characteristic: Contact discharge 6kV
Air discharge 8kV
5.6 Surge Capability
Test according to EN61000-4-5
Test characteristic: line to line: 1kV Surge
line to earth: 2kV Surge
5.7 Immunity to conducted disturbances
Test according to EN 61000-4-6
Test characteristic: 150kHz – 80 MHz; 80% AM (1kHz), 3V