Datasheet
PRODUCT SPECIFICATION Open Frame
Page 10/12
Document prepared and responsible for
M. Mauritz
E2OFxW3 60
Approved by
Day
Month
Year
Revision
S. Schmalhofer
20
01
15
I
5 SAFETY
5.1 Dielectric Strength
The input isolation test voltage is
3kV AC for standard and household applications
4KV AC for medical application,
Sinusoidal waveform, test duration is 2 seconds for 100% test, 1minute for lot-test.
5.2 Over-current Protection
The unit is not long time over-current proof. If the unit is powered in overload conditions,
the device can be damaged. Over load does not cause any damage to persons or ambient
(fire, explosions, etc).
5.3 Single Component Failure
A single component failure does not cause any damage to persons or ambient (fire,
explosions, etc).
5.4 Short Circuit
The power supply is designed with a short circuit protection. A shortened output does not
cause any damage to persons or ambient (fire, explosions, etc.) After removing these
conditions the unit fulfills the specification.