Alarm Controller Fire and CO Model: Ei450 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Smoke Alarm. The leaflet should be regarded as part of the product. If you are just installing the unit, the leaftet must be given to the householder. The leaflet is to be given to any subsequent user.
Contents Page 1. Overview ........................................................................................................ 3 2. Installation ...................................................................................................... 6 3. House Coding ................................................................................................ 8 4. Operation ....................................................................................................... 13 5.
1. Overview Congratulations on purchasing the Ei450 single button alarm controller for RadioLINK Fire and Carbon Monoxide (CO) Alarm systems. The Ei450 tests and controls fire, CO and hybrid (Fire + CO) RadioLINK Alarm systems.
Fire Indicator Low Battery Indicator Light Segments (4) Segment Colour CO Indicator Test / Control Button Activity Function enabled RF signal activity Function complete Fire / CO Alarm Controller 4
Wireless Smoke Alarm System RF Smoke Alarm RF Smoke Alarm rks Wo ith w Wireless Smoke & Carbon Monoxide Alarm System RF Smoke Alarm RF CO Alarm Alarm Controller Model No.
2. Installation Install the Ei450 mounting plate at an accessible point on the wall 1.4M +/- 200mm from floor level. If it intended for a disabled person to operate the controller, an alternative mounting location should be considered. Also consider security and chose a location where it will not be accidently or otherwise operated. MODE ON POWER OFF H.CODE Turn on the system by sliding the switch to the on position.
Check the power up sequence • • • • • Fire, Battery & CO icons flash Each individual segment lights up red Each individual segment lights blue Each individual segment lights green All lights are off to indicate standby mode Fire / CO Alarm Controller Fire / CO Alarm Controller Fire / CO Alarm Controller Repeat this procedure for all Alarms and RadioLINK devices in the system. 7 OFF POWER ON MODE All RadioLINK devices, Smoke Alarms, CO Alarms, control switches, etc.
3. House Coding H.CODE OFF POWER ON Press and hold the House Code switch on the back of the controller until all segments light up blue, then release. The segments will flash rapidly for a moment on entering house code (H CODE). WARNING MODE It is essential to House Code the Ei450 i-controller to all the other RadioLINK Alarms and devices in the system to ensure they will not communicate with nearby systems. Failure to house code the system may also result in a system malfunction.
Return to the Ei450 i-controller and check that all 4 segments (ring) are flashing blue. The number of flashes should equal the number of RadioLINK devices in the system. A system with 3 smoke alarms, one CO alarm and the i-controller will result in five blue flashes. The flash pattern will repeat every 5 to 10 seconds while the i-controller remains in house code. If it fails to flash the correct number of times, then consult the “Troubleshooting the RF link” section of this instruction manual.
Do not do this until the house coding procedure has been completed! 10 OFF POWER ON ON POW Fire / CO Alarm Controller MODE If you choose to make the switch tamper proof remove the pip (plastic post) using a pliers or similar tool. MODE To manually exit house code press the house code button on the back of the Ei450 switch. When all the segments light up blue, release the button. This unit will then send a “Cancel” signal to all the other RadioLINK devices to exit House code.
Slide the Ei450 onto the mounting base on the wall. Fire / CO Alarm Controller Check that the RadioLINK system is working by pressing the button on the Ei450 i-controller until the TEST segment lights blue. This indicates a RadioLINK test signal has been activated. All the Alarms in the system will sound for a short period and then stop. If the test fails go to Troubleshooting the RF link section.
Reset the house code To reset the other Alarms and accessories in the system consult the appropriate instruction manuals. 12 OFF POWER ON MODE To reset the Ei450 i-controller press and hold the house code switch. All segments will flash blue briefly and then go solid. After 5 seconds approx. the segments will start flashing blue. At this point release the house code switch. The Ei450 has now been reset. H.CODE Sometimes in order to resolve an RF communication issue, e.g.
4. Operation Frequent testing of the system is advised to ensure its continued and safe operation. Guidelines and best practices for testing are as follows: 1. After the system is installed. 2. Once weekly thereafter. 3. After prolonged absence from the dwelling (.e.g. after holiday period). 4. After repair or servicing of any of the systems elements or household electrical works. WARNING Testing the alarm system Press the button on the Ei450 i-controller until the TEST segment lights up blue.
When the alarm system sounds If there is a fire, immediately evacuate the premises and telephone the fire brigade. If the source of the alarm is not obvious go to the Ei450 i-controller and check to see which indicator is illuminated, Fire or CO. If the CO indicator is flashing, open doors & windows while evacuating the premises. Telephone the appropriate authorities to report the incident.
If you are satisfied there is no fire but the Smoke/Heat Alarm is still continuing to alarm you may now silence the system. Wait until the SILENCE segment is flashing red and then press the button. The SILENCE segment will turn blue, the Alarm(s) will stop sounding and all segments on the controller will flash green momentarily to indicate that the Controller is back in standby. The Alarms in the system will be silenced for the next 10 minutes.
4. When the FIRE icon stops flashing, the memory recall is complete, the Alarm will stop sounding and the Alarm controller will return to standby with all segments extinguished. 5. The memory is now erased and pressing the button again will perform a normal test. CO Memory 1. The CO memory feature enables the identification of a CO Alarm that has previously been activated, e.g. a CO incident while the house was not occupied.
5. System Diagnostics The system diagnostic features are intended to assist professional installation and maintenance personal to install, commission and maintain the RadioLINK fire and control systems utilising the Ei450 i-controller. These features are not intended for the home owner / tenant and should only be used by personnel described above. The alarm identification test only works with some RadioLINK Alarms.
With the Ei450 in your hand press and hold the button. Walk around the house and verify that each Alarm is sounding. When testing is complete release the button and replace the controller in its cradle. If the test fails go to Troubleshooting the RF link section. Fire / CO Alarm Controller System Diagnostic Mode OFF H.CODE A special system diagnostic mode will facilitate the following special tests. MODE ON POWER 1. Two minute “Long Test”.
Two minute - Long Test On entering the system diagnostic mode the TEST segment will flash green inviting you to press the button. When you press the button the segment will turn blue and all the Alarms in the system will sound for 2 minutes. This will allow you to walk around the house and verify that each individual Alarm is sounding. Fire / CO Alarm Controller Fire / CO Alarm Controller The test will automatically cease after 2 minutes or if the button is pressed again.
Fire / CO Alarm Controller Fire / CO Alarm Controller This will then locate the Alarm that was previously active and cause it to sound for a number of seconds (depending on the number of RadioLINK devices in the system). Pressing the button again will cause it to sound again. This allows you to walk around the house until you have found the active Alarm. All segments will flash green.
6. Guarantee Ei Electronics guarantees the (‘Model Ei450’) for 5 years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee excludes replaceable batteries. This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused. This guarantee excludes incidental and consequential damage.
7. Troubleshooting the RadioLINK If, when checking the RadioLINK interconnection, some of the Alarms do not respond to the Ei450 remote control test, then: (i) Ensure the Ei450 controller has been activated correctly. Check that the power on procedure operates as described in the installation section. (ii) Repeat House Code procedure (see section 2). (iii) Relocate the Ei450 controller and/or rotate/relocate the RadioLINK Alarms.
8. Limitations of Radio Communications Ei Electronics radio communication systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range (required by regulatory bodies) there are some limitations to be considered: (i) Radio equipment, such as the Ei450 controller, should be tested regularly - at least weekly. This is to determine whether there are sources of interference preventing communication.
The user is encouraged to eliminate the interference by one or more of the following measures: (i) Re-orientate or re-locate the unit. (ii) Increase the distance between the Ei450 and the device being affected. (iii) Consult the supplier or an experienced radio/television technician. 9.
10. Getting the Ei450 serviced OFF POWER MODE ON If it needs to be returned for repair or replacement, slide the switch to the off position, place it in a padded box and send it to “Customer Assistance and Information” at the nearest address given on the unit or in this leaflet. H.CODE If your Ei450 fails to work after you have carefully read all the instructions and checked that the unit has been installed correctly contact Customer Assistance at the nearest address given at the end of this leaflet.
Block E1 The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream. Proper disposal will prevent possible harm to the environment or to human health. When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner.
Aico Ltd Mile End Business Park, Maesbury Road, Oswestry, Shropshire SY10 8NN, U.K. Telephone: 0870 7584000 www.aico.co.uk Ei Electronics Shannon Industrial Estate, Shannon, Co. Clare, Ireland. Telephone: +353 (0)61 471277 www.eielectronics.