Specifications

7. Carefully align the mounting plate and screw into place. Connect the wires to the terminal block. With
recessed wiring, ensure the rear gasket seals around the edge of the hole in the ceiling or wall. This is
to prevent air draughts affecting the CO gas entering the alarm. If the hole is not closed off by the gasket
it should be sealed with silicone rubber or equivalent.
Note: House wiring should not be “bunched up” in the area of the alarms but quickly and neatly directed
away. This will minimize their effect on the radio aerial.
8. Replace the wiring cover.
9. Carefully line up the unit on the base and slide on.
10. It is essential
to House Code the RadioLINK Ei262 to ensure they will not accidently
communicate with nearby systems (even if you do not plan to use the RadioLINK feature yourself).
This is easily done as explained in Section 4.2.
L N IC
EARTH (IF PRESENT)
L - LIVE
N - NEUTRAL
IC - INTERCONNECT
TERMINAL SCREWS
RECESSED WIRING AREA
MAINS WIRING
16
L N IC
KNOCK OUT FOR
SURFACE WIRING
CONDUIT
WIRING
CONDUIT
INSERT SCREWDRIVER TO LIFT
AND REMOVE WIRE COVER
KNOCK OUT
FOR SURFACE WIRING
CONDUIT
SEALING GASKET
(MUST BE IN PLACE)
WIRING
CONDUIT
Figure 5 - Surface Wiring
Figure 6 - Recessed Wiring
B16587-R0-262-UC-ENG 15/4/09 3:38 PM Page 16