Installation guide

HDLC Status 135
Protocol state
The current status of the HDLC protocol.
Line state
The current status of the line itself.
TRANSPAC X.32 CID and TRANSPAC X.32 SID
These fields are
displayed only when an X.32 selection is made in the Eicon Configuration
Program. The TRANSPAC X.32 CID is a code that identifies you to other
systems. This is useful when you are using a dial-up line and the temporary
DTE address is insufficient to properly identify you.
ERIPAK
This field is displayed only when an ERIPAK selection is made in the
Eicon Configuration Program. The ERIPAK CID is a code that identifies you
to other systems. This is useful when you are using a dial-up line and the
temporary DTE address is insufficient to properly identify you.
CCITT X.32
This field is displayed only when a CCITT X.32 selection is
made in the Eicon Configuration Program. The CCITT X.32 is a code that
identifies you to other systems. This is useful when you are using a dial-up line
and the temporary DTE address is insufficient to properly identify you.
Value Description
Closed Protocol not activated.
Closing Terminating HDLC protocol.
Opening Activating HDLC protocol.
Opened HDLC active (Data mode).
Resetting HDLC line is resetting (Sent or received a SABM).
Wait Reset Waiting for a remote to reset the HDLC line.
Wait Open When passive or DCE, wait for remote to activate the line using
SABM.
XID Send An X.32 XID has been sent.
XID Recv Wait for an X.32 XID from remote.
Value Description
Closed Line is closed.
Closing Line is closing.
Opening Opening the line.
Opened Line is ready.
Delaying Waiting for a small delay in order to re-open the line.