Installation guide

About ECMODULE 99
About ECMODULE
ECMODULE is used to examine the protocol information streaming through
the SNA Gateway PC, and to provide statistical information about the various
connections.
ECMODULE consists of four main parts:
ECMODULE STATUS: provides global information on the status of all
applications running on the gateway PC. Information about connection
status for all established links on each Eiconcard is presented.
Application Protocol Connection Port
Name Name ID State
----------------------------------------------------------------------------
Card number : 1
APPCLIB APPC 1 CONNECTED @10:33:55 Nov 27 1
APPCLIB APPC 2 CONNECTED @10:38:33 Nov 27 1
ACCESSW SDLC 3 CONNECTED @10:38:35 Nov 27 2
Card number: 2
ACCESSD X25 4 CONNECTED @11:00:34 Nov 27 3
ECMODULE STATUS protocol: this derivative of ECMODULE STATUS
provides detailed information about the status of the specified protocol that
the gateway PC is using. Information about the protocol configuration,
status, and connections is presented.
X.25 Loadable Module Status
Port number: 01 Port name: P1
Default Maximum
Window size..................: 2 7
Packet size (bytes)..........: 256 256
Packet format................: Extended Maximum retry count N3......: 3
Restart timer T20 (sec)......: 60 Reset timer T22 (sec).......: 60
Call timer T21 (sec).........: 60 Clear timer T23 (sec).......: 60
Idle timer (sec).............: 0 Acknowledgement timer (msec): 20
Two-way VCs configured.......: 8 Permanent VCs configured....: 0
In-coming VCs configured.....: 0 Out-going VCs configured....: 0
Trace........................: Off Trace buffer size (bytes)...: 0
Trace filter (hex)...........: 00 Trace entry size (bytes)....: 0
Link activated at............: @21:07:08 Jan 16
Last restart.................: @21:07:08 Jan 16
VC Local Address Remote Address Type Status
----------------------------------------------------------------------------
8 5540034622 2Way Circuit Ready @05:11:41 Jan 17