Installation guide

Installation in Unattended Mode 97
RBSNoAnswerSupervision:
For GroundStart and LoopStart trunk modes only. Answer Supervision detects when
the remote side answers a call and thus ensures accurate billing of a call. Possible settings
are:
0 (off): Answer supervision is disabled and the standard connection detection based
on tones is used.
1 (on): Answer supervision is enabled and the line detects when the remote side
answers a call.
Specific parameters for Q-Sig
QSIGPBXType
QSIGPBXType defines the type of your PBX. If your PBX is not listed, use the value for
Generic PBX. Possible settings are:
0: Generic PBX
1: Siemens HICOM 300
2: Siemens HICOM 150
3: Alcatel 4400, 4410, 4200
4: Ericsson MD110
5: Ericsson BP250
6: Lucent Definity
7: matra6500
8: Nortel
QSIGStandard:
Set the QSIGStandard that is required for the selected Q-Sig PBX type. Possible settings
are:
0: Automatic
1: ISO
2: ECMA
3: ECMAV1
4: ECMAV2
For the proper setting refer to the documentation that came with your PBX.