Instruction manual

LAMP REPLACEMENT
WHEN THE PROJECTION LAMP OF THIS PROJECTOR DRAWS TO AN
END, THE LAMP REPLACEMENT INDICATOR LIGHTS YELLOW AND THE
WARNING MESSAGE “LAMP REPLACEMENT” APPEARS AS THE RIGHT
FIGURE. WHEN THE WARNING MESSAGE IS DISPLAYED, THE
PROJECTION LAMP SHOULD BE REPLACED.
To terminate the warning message.
Replace the Projection Lamp and reset the LAMP REPLACEMENT
MONITOR TIMER (See “LAMP AGE” section on page 52.), and the
warning message is terminated.
To erase the warning message in a moment
.
To erase the warning message for a moment, move the arrow to “YES” by
pressing the POINT UP/DOWN BUTTON(s) and then press the SELECT (REAR
CLICK) BUTTON. This procedure is temporary measure, and the warning
massage appears again when the projector is turned on next time.
• For continued safety, replace with a lamp assembly of the same type.
• Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the
projector can become very hot.
• Do not drop the lamp module or touch the glass bulb I The glass
can shatter and cause injury.
Follow these steps to replace the lamp assembly.
1. Turn off the projector and allow the projector to cool thoroughly.
2. Disconnect the AC cord from the projector.
3. Remove 2 screws with a screwdriver and remove the lamp cover.
4. Remove 2 screws with a screwdriver and pull out the lamp assembly by
grasping the handle.
5. Replace the lamp assembly.
6. Tighten 4 screws to secure the lamp cover to the lamp assembly.
7. Connect the detachable AC cord to the projector.
8. Reset the lamp replacement monitor timer.
(See “LAMP AGE” section on page 52.)
NOTE: Do not reset the LAMP REPLACEMENT MONITOR TIMER, except
after the lamp is replaced.