9. Technische Daten
PIN Nr.: ....................................................................................................................................51BT3668
Bestimmungsland: ......................................................................................................................... DE-AT
Nennwärmebelastung Qn: ............................................................................................................ 4,2 kW
Gas asche: ....................................................................................... Camping 5 kg – 11 kg (max. 13 kg)
Gastyp: .............................................................................Propan, Butan oder Propan-Butan Gemische
Gasverbrauch G30 (Butan): .........................................................................................................305 g/h
Gasverbrauch G31 (Propan): ........................................................................................................300 g/h
Zündung: ..............................................................................................................................Piezozünder
Sauersto mangelsicherung ..............................................................................................................ODS
Die Sauersto mangelsicherung (ODS) schaltet die Gaszufuhr ab, falls die CO2 Konzentration im Raum
auf etwa 1.0% ansteigt. Verwenden Sie nur einen geeigneten Druckregler der den technischen Daten
des Heizgerätes entspricht.
Nationalitätskennzeichen Kategorie P(mbar) Gas Düse(1/100 mm)
AT-DE-CH I3B/P 50 G30/G31 51/71
FR-GB-IE-PT I3B 28-30 G30 59/79
BE-CH-ES
GR- IT-PT
I3+ 28-30/37 G30/G31 59/79
CY-CZ-DK-EE
FI-GR-IT-LT-LV
MT-NL-NO-SE
SI-SK-BG-RO-TR
I3B/P 28-30 G30/G31 59/79
PL I3B/P 37 G30/G31 55/77
Anl_KGH_4200_D.indb 12Anl_KGH_4200_D.indb 12 26.03.15 10:1026.03.15 10:10