interface bridge 0
no shutdown
ip address 192.168.0.1
exit
interface wireless 0 bridge-group 0
interface FastEthernet 0 bridge-group 0
copy running-configuration startup-configuration
reboot
3.3. LibraPlus Point-to-Multipoint Quick Setup
This section explains how to configure a LibraPlus Master and Client radio for simple point to multipoint
communication. Using this example will configure a link without any additional features such as se-
curity, routing, filtering, or VLAN
Note that the distance in this example is set to 300 for bench testing. When the units are deployed in
the field, this value should be changed to the appropriate link distance.
Default LibraPlus IP address 192.168.0.5
Login to the unit using a SSH enabled utility such as Putty
Default username: admin
Default password: 123
3.3.1. CPE Unit
Use the following commands to configure the CPE side.
EION:
interface wireless 0
type station
ssid Eion
mode a
speed auto
channel 5805
tx-power 26 (use the maximum if field installation)
no rts
distance 300 (use the real distance if field installation)
wds-mode
fast-frame
polling
no burst
no compression
no wmm
no dfs
no atpc
no shutdown
exit
EION:
interface FastEthernet 0
ip address 192.168.0.5 255.255.255.0 (IP to be modified)
no shutdown
exit