Figure 5:3 Surge Suppressor Sides
5.4.4 Surge Suppression Unit Location
Lightning arrestors and surge protectors should be installed at all input/ output points
on the LibraPlus equipment. Additionally, they should be properly grounded by
connecting the body of the arrestor or protector to the grounding system with a heavy
gauge (6 AWG) copper wire. This grounding wire should be as short as possible.
The following figures illustrate the locations where the surge suppressors must be
installed, when cabling a LibraPlus 5860.
LibraPlus 5860 User Guide Pre-installation: Grounding Page 24 of 95