I ndication Possible Cause Corrective Action
No communication
between units
Conf iguration problems Check the following configuration
settings:
MAC Address–Each unit must
have a unique MAC Address
Center frequency–Units must
have the same center
frequency to communicate
IP address/subnet mask
Incorrectly conf igured
IP addresses result in units
being unable to communicate.
Check that I P addresses are
unique for each unit within a
subnet and that the correct
subnet mask is being used.
Poor Link
Performance
Distance
Check the distance
conf iguration setting on Slave
Poor Link
Performance
Signal absorption
Check LOS for obstacles such
as trees
Change alignment of antenna
to take advantage of
benef icial multipath signals
Move antenna to better
location or remove obstacle if
possible
Poor Link
Performance
Interference
Set units from different
systems in the same
geographical area to different
center frequencies.
Overlapping wavelengths from
other systems will degrade
performance.
Poor Link
Performance
Overpowering Co-
located Unit
Output power from one unit
can overpower another, co-
located, radio, even if units
operate on different channels
New conf iguration
will not take
Incorrectly upgraded
software
Reload the software image