Drawing : - TPC575 Issue :-1 Date : - 08/02/22 CD425 (10149BR-US) INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 CD425 PACKAGE CONTENTS Item Description Quantity 10149BR-US Dehumidifier 1 3944110 Reinforced tubing – 16mm I/D 1 TPC575 Manual 1 Page 2 of 16
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 UNPACKING Carefully remove the CD425 dehumidifier unit from its packing and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, as it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The Ebac CD425 dehumidifier removes moisture from the air that circulates through it.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 SPECIFICATIONS MODEL: CD425 HEIGHT: 1193 mm (47”) WIDTH: 1092 mm (43”) DEPTH: 482 mm (19”) WEIGHT: 160 kg (353 lbs) AIRFLOW: 1750 CFM (2975M3/Hr) TOTAL POWER: 3680 (MAX) MAXIMUM OPERATING TEMPERATURE: 35ºC (95ºF) POWER SUPPLY: 460V 3PH 60Hz REFRIGERANT: R407c CHARGE: 2.5Kg "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 SYSTEM INSALLATION WIRING Connect a suitably fused 460V 60Hz 3 phase mains power supply to the MAINS T/B terminal block inside the electrical box located at the control panel end of the machine. DRAINAGE The appliance is fitted with a condensate pump which collects all the condensate.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 OPERATION The CD425 is a self contained low temperature dehumidifier. All electrical contactors, overloads, etc are housed in an electrical box built inside the unit. The unit is equipped with a defrost valve which energized automatically to clear any ice formation on the evaporator coils. This allows the unit to operate at much lower temperatures; the control panel gives indication of the set humidity, drying and defrost status.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 f) Observe the evaporator coils i) If the air temperature is below 20°C, an even coating of ice should cover the entire evaporator coil ii) If the temperature is above 20°C, droplets of condensed water should cover the entire evaporator coil. 4. Leave the unit to run for approximately 42minutes (from compressor starting), after which the unit should go through a 4 minute defrost cycle.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Check the power from the power supply panel 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center Unit inoperative 1. No power to unit Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 SPARE PARTS LIST DESCRIPTION Dehumidifier Controller Display PCB Humidity Sensor PCB LED Board Cable Humidity Sensor Cable Keypad Label Capillary Tube Condenser Coil Evaporator Coil Defrost valve Filter Dryer Fan Motor Contactor (Fan) Contactor (Compressor) Auxiliary contact (Fan) Solenoid Coil Transformer (230V – 12V) Transformer (460V – 220V) Terminal Block Overload Coil Sensor Humidity Sensor Housing PCB Jumper Socket MCB (16A) MCB (2A) Axial Fan Standoff L
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 ww.EIPLDIRECT.com LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 Page 14 of 16
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 Page 15 of 16
Drawing : - TPC575 Issue :-1 Date : - 08/02/22 UK Head Office American Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590 Tel: +01 757 873 6800 Fax: +01 757 873 3632 www.eipl.co.uk sales@eipl.co.uk www.ebacusa.com sales@ebacusa.