Drawing : - TPC452 Issue :-4 Date : - 13/10/17 K100E DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 K100E PACKAGE CONTENTS Item Description Quantity 10185GE-US Dehumidifier 1 off 3086144 Quick release hose coupling 1 off 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit. The resulting reduction of relative humidity helps prevent rust, rot, mold, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 Download the app from apps.ebacusa.com The K100E dehumidifier is a rugged reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. A powerful and reliable reverse cycle defrost system, controlled by an electronic timer, guarantees positive de-icing and thereby optimizing operation at low temperatures.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 SPECIFICATIONS MODEL: 10185GE-US HEIGHT: 27.2” (692mm) WIDTH: 22.8” (580mm) DEPTH: 18.3” (464mm) WEIGHT: 117 Lbs (53Kg) AIRFLOW: 300 CFM (510 M3/Hr) POWER SUPPLY: 110V 1Ph 60Hz POWER 1500 W (max) FINISH: Epoxy coated steel REFRIGERANT TYPE/QTY: R407C (540g) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit must have a clearance of 0.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 OPERATION The following procedures should be followed to test the K100E for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded electrical outlet. 2. Setting the Digital Humidistat Turn fully clockwise • 3.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 If, after carrying out the above procedures, the unit does not appear to function properly, refer to the Trouble Shooting section, which follows, or contact the Factory Service Center. CAUTION: ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT LEAST FIVE MINUTES BEFORE RESTARTING. Discharge Pump The pump works automatically and periodically pumps away collected moisture to a drain or container. The pump is capable of discharging water to a vertical height of 20ft.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the correct replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any licensed refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 K100E SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 HUMIDITY SENSOR 1619514 1 2 DEFROST TIMER 1619516 1 3 CAPILLIARY TUBE .047 2pcs.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 Page 15 of 16
Drawing : - TPC452 Issue :-4 Date : - 13/10/17 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.