Drawing : - TPC450 Issue :-1 Date : - 18/01/16 K100H DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 K100H PACKAGE CONTENTS Item Description Quantity 10185GH-US Dehumidifier 1 off 3086144 Quick release hose coupling 1 off 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit. The resulting reduction of relative humidity helps prevent rust, rot, mold, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 SPECIFICATIONS MODEL: 10185GH-US HEIGHT: 27.2” (692mm) WIDTH: 22.8” (580mm) DEPTH: 18.3” (464mm) WEIGHT: 117 Lbs (53Kg) AIRFLOW: 300 CFM (510 M3/Hr) POWER SUPPLY: 110V 1Ph 60Hz POWER 1500 W (max) FINISH: Epoxy coated steel REFRIGERANT TYPE/QTY: R407C (540g) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. WIRING: Connect the power mains cable to a designated 30 Amp breaker.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 OPERATION The following procedures should be followed to test the K100H for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded electrical outlet. 2. Setting the Digital Humidistat The Digital Humidistat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 i. If the air temperature is below 80°F, an even coating of frost should cover the entire evaporator coil ii. If the air temperature is above 80°F, frost and/or droplets of condensed water should cover the entire evaporator coil. F. After continuous running time of approximately 55 minutes, the unit will enter “Hot Gas” defrost mode for 5 minutes and then automatically return to normal operation.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, AND 4. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the correct replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any licensed refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 K100H SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 DEFROST TIMER 1619508 1 2 CAPILLIARY TUBE .047 2pcs.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 Page 13 of 16
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 Page 14 of 16
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 Page 15 of 16
Drawing : - TPC450 Issue :-1 Date : - 18/01/16 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.