Drawing : - TPC519 Issue :-1 Date : - 03/03//20 RM40-SH INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 RM40-SH PACKAGE CONTENTS Item Description Quantity 10187SH-US Dehumidifier 1 3014338 PVC tube – 12mm I/D 3M 3086101 Jubilee clip 1 TPC519 Manual 1 Page 2 of 12
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 UNPACKING Carefully remove the RM40-SH dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The RM40-SH industrial dehumidifier removes moisture from the air through the refrigeration process.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 SPECIFICATIONS MODEL: RM40-SH HEIGHT: 11.8” (300mm) WIDTH: 13” (330mm) DEPTH: 21.7” (550mm) WEIGHT: 50 lbs AIRFLOW: 129 CFM (220M3/hr) MAX OPERATING TEMP: 95ºF POWER SUPPLY: 110V, 60Hz REFRIGERANT TYPE: R410a "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 OPERATION The operation of the dehumidifier is to remove moisture from the air by having it condense on the cold tubes of the evaporator coil. The air then passes over the hot condenser coil and returns to the conditioned space slightly warmer and dryer than when it entered the dehumidifier unit. TEST FOR CORRECT OPERATION The following procedures should be followed to test the RM40-SH for correct operation. 1.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Check the power from the power supply panel. 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center Unit inoperative 1.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 RM40-SH SPARE PARTS LIST NUMBER 1 2 3 4 5 6 7 8 9 10 11 DESCRIPTION Timer Refrigerant Coil Set Capillary Solenoid valve Filter dryer Solenoid coil Fan Motor Fan Blade Compressor Humidistat Mains Cable Page 9 of 12 PART NUMBER 1619519 2018743 3014254 3020836 3020937 3030451 3947012 3947014 3944954 3035158 2141095 QUANTITY 1 1 1.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 Page 11 of 12
Drawing : - TPC519 Issue :-1 Date : - 03/03//20 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.