Drawing : - TPC442 Issue :-2 Date : - 24/11/16 DUAL VOLTAGE RM85-H INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 INTRODUCTION Designed for a wide range of applications, the RM85H is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 Remove the lower screw and swing the cover to one side to reveal the access hole. The switch lever can be seen through the hole. Using a flat blade screwdriver move the switch lever down to the 230 volt position. (If 110 volt is required the switch lever must be in the upper position) Once the required voltage has been selected, refit the cover and tighten the lower fixing screw. The dehumidifier is now ready to be connected to the required power supply.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 BACK SHELL REMOVAL To remove the back shell and access the voltage selection switch please carry out the following steps.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 SPECIFICATIONS MODEL: 10560HD-GB HEIGHT: 945 mm WIDTH: 545 mm DEPTH: 492 mm WEIGHT: 48 kg AIRFLOW: 390 M3/Hr POWER SUPPLY: 230V/115V / 50Hz/ 1 ph FINISH: Rotational Moulded polyethylene OPERATING RANGE: 3ºC – 35ºC REFRIGERANT: R407c (500g) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 OPERATION The following procedures should be followed to test the RM85 for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Ensure the correct voltage has been selected. Connect the drainage outlet to a suitably sized hose and run the hose to a permanent drain 2.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 F. When the unit is operated in ambient of less than 15°C, a defrost cycle should occur approximately every hour. The exact time is impossible to predict as the unit is fitted with a temperature sensitive defrost control. When the unit is defrosting, the % Relative Humidity displayed on the digital controller may increase as a result of the ice / frost melting.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit 2. Mains cable damaged. Little or no airflow 1. Fan motor burnt out 2. Dirty refrigeration coils 3. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 RM85 SPARE PARTS LIST NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16 17 18 19 20 21 22 23 24 DESCRIPTION Timer Condenser coil Evaporator coil Cable & Tube wrap Drain tray Filter Capillary Solenoid valve Filter dryer Compressor Defrost Relay Voltage selection capacitor Solenoid coil Humidity Controller Transformer Voltage selection switch Run capacitor On/Off switch Power Relay Pump purge switch Fan Fan inlet ring Wheel Rubber foot Condensate pump PART NUM
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 Page 13 of 16
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 Page 14 of 16
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 Page 15 of 16
Drawing : - TPC442 Issue :-2 Date : - 24/11/16 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.