English Deutsch Important: Please read this “Instructions for Use”, and Installation Manual (on the CD-ROM) carefully to familiarize yourself with safe and effective usage. Please retain this manual for future reference. • The latest "Instruction for Use” is available for download from our web site: http://www.eizo.
Monochrome LCD monitor English Instructions for Use
SAFETY SYMBOLS This manual and this product use the safety symbols below. They denote critical information. Please read them carefully. WARNING CAUTION Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Indicates an attention to be required. For example, the symbol such as “the risk of electric shock”. Indicates a prohibited action.
PRECAUTIONS • This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is used outside the region, it may not operate as specified in the specifications. • To personal safety and proper maintenance, please read carefully this section and the caution statements on the monitor. Location of the Caution Statements Symbols on the unit Symbol This symbol indicates Main Power Switch: Press to turn the monitor’s main power off.
WARNING If the unit begins to emit smoke, smells like something is burning, or makes strange noises, disconnect all power connections immediately and contact your local EIZO representative for advice. Attempting to use a malfunctioning unit may result in fire, electric shock, or equipment damage. Do not open the cabinet or modify the unit. Opening the cabinet or modifying the unit may result in fire, electric shock, or burn. Refer all servicing to qualified service personnel.
Handle the power cord with care. English • Do not place the cord underneath the unit or other heavy objects. • Do not pull on or tie the cord. If the power cord becomes damaged, stop using it. Use of a damaged cord may result in fire or electric shock. For the electrical safety, do not connect or disconnect the power cord in the presence of patients. Never touch the plug and power cord if it begins to thunder. Touching them may result in electric shock.
CAUTION Handle with care when carrying the unit. Disconnect the power cord and cables when moving the unit. Moving the unit with the cord attached is dangerous. It may result in injury. Carry or place the unit according to the correct specified methods. • When carrying the unit, grasp and hold firmly as shown in the illustration below. • Do not unpack or carry the unit only by a single person, since the large size unit is so heavy. Dropping the unit may result in injury or equipment damage.
Notice for this monitor This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is used outside the region, it may not operate as specified in the specifications. This product may not be covered by warranty for uses other than those described in this manual.
Cleaning Attention • Chemicals such as alcohol and antiseptic solution may cause gloss variation, tarnishing, and fading of the cabinet or panel, and also quality deterioration of the image. • Never use any thinner, benzene, wax, and abrasive cleaner, which may damage the cabinet or panel. Note • The optional ScreenCleaner is recommended for cleaning the cabinet and panel surface. The stains on the cabinet and panel surface can be removed by moistening part of a soft cloth with water.
CONTENTS English Cover....................................................................... 1 PRECAUTIONS....................................................... 3 ●●IMPORTANT.................................................... 3 Notice for this monitor.......................................... 7 Cleaning..................................................................... 8 To use the monitor comfortably.............................. 8 CONTENTS..........................................................
Chapter 1 Introduction Thank you very much for choosing an EIZO monochrome LCD monitor. 1-1. Features • 21.3 inches • Supports a resolution of 5M pixels (Portrait: 2048 × 2560 dots (H × V)) • Uses high-contrast panel (1200:1). Enables the display of sharp images. • Applicable to DisplayPort (applicable to 8 bit or 10 bit, not applicable to audio signals) • The Hybrid Gamma function automatically identifies the display area for the medical and other images on the same screen, and displays each set status.
Attention 1-2. Package Contents Check that all the following items are included in the packaging box. If any items are missing or damaged, contact your local EIZO representative. Note • Please keep the packaging box and materials for future movement or transport of the monitor.
1-4. Controls and Functions 8 7 17 16 Adjustment menu*1 1 2 3 1. Presence Sensor button 2. 3. button button 4. button 5. 6. button 7. Ambient Light Sensor 8. Integrated Front Sensor (slide type) 9. Main power switch 10. Power connector 11. PS/2 connector 12. 13. 14. 15. 16. 17. 18. *1 12 4 5 6 9 10 11 18 12 13 1415 Detects the movement of a person in front of the monitor. Switches the CAL Switch mode. Cancels the setting/adjustment and exits the Adjustment menu.
Chapter 2 Setting Up English 2-1. Compatible Resolutions The monitor supports the following resolutions. √ : Supported Resolution vertical Applicable scan signal frequency Dot Clock 720 × 400 VGA TEXT 70 Hz 640 × 480 VGA 60 Hz 800 × 600 VESA 60 Hz 1024 × 768 VESA 60 Hz 1280 × 1024 VESA 60 Hz 290 MHz 1600 × 1200 VESA 60 Hz (Max.
Digital connection (DisplayPort) Digital connection (DVI) Signal cable: DisplayPort - DisplayPort (supplied) or Signal cable: DVI-D - DVI-D (Dual Link) (supplied) 3. Plug the power cord into a power outlet and the power connector on the monitor. 4. Connect the USB cable when using RadiCS LE or ScreenManager Pro for Medical. Connecting to the Monitor 5. Press Connecting to a Computer to turn on the monitor. The monitor’s power indicator lights up green. 6. Turn on the PC.
Chapter 3 Troubleshooting Problem 1. No picture • Power indicator does not light. • Power indicator is lighting orange and green. • Power indicator is flashing orange and green. 2. The message below appears. Possible cause and remedy • • • • Check whether the power cord is connected properly. Turn the main power switch on. Press . Turn off the main power, and then turn it on again a few minutes later. • Switch the input signal. For details, refer to the Installation Manual (on the CD-ROM).
●●Error code table Error Code 16 Description 0*** • Errors that occurred during SelfCalibration 1*** • Errors that occurred during Grayscale Check *1** • Errors that occurred during DICOM *2** • Errors that occurred during CAL1 *3** • Errors that occurred during CAL2 **10 • The product maximum brightness may be lower than the target brightness. • Lower the target brightness. **11 • The product minimum brightness may be higher than the target brightness. • Raise the target brightness.
Chapter 4 Specifications Size 21.3-inch (540 mm) Type TFT monochrome LCD, LED backlight Surface treatment Anti-glare Surface hardness 2H Viewing angles Horizontal 176˚, vertical 176˚ (CR≥10) Dot pitch 0.165 mm Response time Black-white-black: Approx.
USB Standard USB Specification Revision 2.0 Port Upstream port × 1, Downstream port × 2 Communication Speed 480 Mbps (high), 12 Mbps (full) 1.5 Mbps (low) Supply current Downstream: Max. 500 mA/1 port Outside Dimensions Unit: mm (inch) 30° TILT 146.5 (5.8) 236 (9.3) 512 (20.2) 455 (17.9) 65.5 (2.58) 99 (3.90) 94.5 (3.72) 171 (6.7) 344° SWIVEL 105 (4.1) 3 (0.12) 350 (13.8) LOWEST POSITION 144 (5.7) 100 (3.9) 144 (5.7) 18 (0.71) 206 (8.1) 320 (12.6) 360.5 (14.2) 629 (24.8) 100 (3.
Chapter 5 Glossary English DDC (Display Data Channel) VESA provides the standardization for the interactive communication of the setting information, etc. between a PC and the monitor. DICOM (Digital Imaging and Communication in Medicine) The DICOM standard was developed by the American College of Radiology and the National Electrical Manufacturer’s Association of the USA. The DICOM compatible device connection enables to transfer the medical image and information.
Appendix Trademark The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing, LLC in the United States and other countries. The DisplayPort Compliance Logo and VESA are registered trademarks of the Video Electronics Standards Association. Acrobat, Adobe, Adobe AIR, and Photoshop are registered trademarks of Adobe Systems Incorporated in the United States and other countries.
Medical Standard English • It shall be assured that the final system is in compliance to IEC60601-1-1 requirement. • Power supplied equipment can emit electromagnetic waves, that could influence, limit or result in malfunction of the monitor. Install the equipment in a controlled environment, where such effects are avoided.
FCC Declaration of Conformity For U.S.A. , Canada, etc. (rated 100-120 Vac) Only FCC Declaration of Conformity We, the Responsible Party EIZO Inc. 5710 Warland Drive, Cypress, CA 90630 Phone: (562) 431-5011 declare that the product Trade name: EIZO Model: RadiForce GX540 is in conformity with Part 15 of the FCC Rules.
EMC Information Essential performance of RadiForce series is to display images and operate functions normally. The RadiForce series requires special precautions regarding EMC and need to be installed, put into service and used according to the following information. Do not use any cables other than the cables that provided or specified by us. Using other cables may cause the increase of emission or decrease of immunity. Cable Length: Max.
Guidance and manufacturer’s declaration - electromagnetic immunity The RadiForce series is intended for use in the electromagnetic environment specified below. The customer or the user of the RadiForce series should assure that it is used in such an environment. Immunity test IEC/EN60601 test level Compliance level Conducted RF IEC/EN61000-4-6 3Vrms 150kHz to 80MHz 3Vrms Radiated RF IEC/EN61000-4-3 3V/m 80MHz to 2.
Recommended separation distances between portable and mobile RF communications equipment and the RadiForce Series NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
China Measures for RoHS Compliance in ChinaRoHS About the Electronic Information Products Pollution Control Symbol This symbol identifies products regulated by the ‘Measures for the Administration of the Control of Pollution by Electronic Information Products,’ and is applicable to electronic information products for sale in the People’s Republic of China.The number in the circle is the Environmentally Friendly Use Period (EFUP).
153 Shimokashiwano, Hakusan, Ishikawa 924-8566 Japan Phone: +81 76 277 6792 Fax: +81 76 277 6793 中国苏州市苏州工业园区展业路8号中新科技工业坊5B Phone: +86 512 6252 0100 Fax: +86 512 6252 1508 Siemensallee 84, 76187 Karlsruhe, Germany Phone: +49 721 20321 0 Fax: +49 721 20321 471 http://www.eizo.com Copyright © 2013 EIZO Corporation All rights reserved. 1st Edition-October, 2013 Printed in Japan. 00N0L834A1 (U.