manual

All disclosures, notices and warranty conditions are being written on the EKWB website. Please read terms of use. Released on 11st of September, 2014.
Installation and mounting manual for EK-XTOP Dual D5 (incl. 2x
pump)
This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability
whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at www.ekwb.com for updates. Before
installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box.
Before you start using this product please follow these basic guidelines:
1. Please carefully read the manual before through before beginning with the installation process!
2. Please remove your motherboard from the computer to assure safest mounting process in order to prevent any possible damages to your CPU and/or motherboard’s circuit board (PCB).
3. The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.
4. The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.
5. EKWB recommends 24 hour leak testing for all EK products before powering on the computer. This will eliminate any damages that may occur because of the users improper installation or
products imperfections.
STEP 1: GENERAL INFORMATION. Sample picture of EK-XTOP D5 (incl. 2x pump) mounted with two Laing D5 PWM/Vario pumps
Picture of enclosed parts in delivery.
STEP 2: IN CASE OF NECESSITY TO DISASSEMBLE THE UNIT.
TY
ASSEMBLING THE “EK-XTOP Dual D5
WITH TWO PUMPS
Take motor with impeller of your Laing D5
PWM/Vario pump. Place it according to right
picture. Do not forget to place o-rings that are
enclosed in “EK-XTOP Dual D5 (incl. 2x
pump)” box. Use enclosed 2,5mm Allen key to
screw the 16 M4×16mm screws on bottom
side to secure the pumps.
Place the o-ring here
Use 14 pcs of M4×16mm
screws to mount the pumps to
the top. Use 2,5mm Alen key.
OUTLET #2
Unused ports have to
be closed with
enclosed G1/4 plugs.
CAUTION!
Top part of the EK-XTOP Dual D5
(incl. 2xPumps) is not symmetrical
therefore please pay attention to
the orientation!
OUTLET #1
Mounting mechanism
Mounting bracket
Preassembled
pump/top combo

Summary of content (2 pages)