Setup Port Baud Rate: CMDIMR_SET_BAUD
Description:
This command is used to setup the transmission speed of a port
specified by the port identifier.
Command Code:
16.
Command Data:
Size of the baud rate parameter in bytes.
Parameters:
The baud rate in bits per second as an unsigned long is passed in the
inbound parameter area.
Data:
None.
Command Word:
0x0Y10 0004
Flags Port ID Command Command Data
E
R
R
R
P
L
C
P
L
U
F
ID
3
ID
2
ID
1
ID
0
C
7
C
6
C
5
C
4
C
3
C
2
C
1
C
0
D
15
D
14
D
13
D
12
D
11
D
10
D
09
D
08
D
07
D
06
D
05
D
04
D
03
D
02
D
01
D0
0
0000YYYY000100000000000000000100
31 28 27 24 23 16 15 8 7 0
Reply:
Flags Port ID Command Command Data
E
R
R
R
P
L
C
P
L
U
F
ID
3
ID
2
ID
1
ID
0
C
7
C
6
C
5
C
4
C
3
C
2
C
1
C
0
D
15
D
14
D
13
D
12
D
11
D
10
D
09
D
08
D
07
D
06
D
05
D
04
D
03
D
02
D
01
D0
0
X110YYYY000100000000000000000100
31 28 27 24 23 16 15 8 7 0
The controller returns with the RPL and CPL flags set.
On error the RPL, CPL and ERR flags are set and an error code is
passed in bits 15:00 of the reply word.
Notes:
The controller accepts all well known baud rates. Furthermore any baud
rate that can be programmed with a resulting error of less than 1% can
be chosen.
The baud rate chosen by this command is retained across openings and
closings.