Operation Manual

4
Some advice
1. Remaincalmandpreferablyrestfor5minutesbeforebloodpressuremeasurement.
2. Thecushouldbeplacedontheupperarmatthesamelevelasyourheart.
3. Duringmeasurement,donotspeakormoveyourbodyandarm.
4. Measurethesamearmforeachmeasurement.
5. Relaxaminimumof3to5minutesbetweenmeasurementstoallowthebloodcirculation
inyourarmtorecover.Prolongedoverinationofthecumaycauseaslightswelling
(ecchymoma)ofyourarm.
6. Removethebatteriesifthemonitorisnotbeusedforamonthormoretoavoiddamageby
batteryleakage.
7. Thisbloodpressuremonitorisdesignedforadultsandshouldneverbeusedoninfantsor
youngchildren.Consultyourphysicianorotherhealthcareprofessionalsbeforeuseon
olderchildren.
8. Bloodpressuremeasurementsdeterminedbythismonitorareequivalenttothoseobtained
byatrainedobserverusingthecu/stethoscopeauscultationmethod.Thesearewithinthe
limitsprescribedbytheAmericanNationalStandard,Electronicorautomated
sphygmomanometers.
9. Pleaseavoidstrongmagneticinterferencesuchasthatfrommobiletelephones,microwave
ovens,etc.
10. Ifanirregularheartbeat–IHB(arrhythmias)isdetectedwhilemakingabloodpressure
measurement,asignalofwillbedisplayed.Thismayaectthefunctionoftheblood
pressuremonitorandresultsmaynotbetotallyaccurate.It’srecommendedthatyou
consultwithyourphysicianforasecondopinion.
11. Makesuretostoreandusethemonitorwithinthetemperatureandhumidityrangesspecied.
Operating procedures
BATTERY
• Insert4xAA1,5Vsizebatteriesinthebatterycompartmentatthebackoftheunit.
Makesurethatthepolaritiesareplacedcorrectly.
• WhentheLCDshowsthebatterysymbol,replaceallbatterieswithnewones.
• Rechargeablebatteriesarenotsuitableforthismonitor.
• Removethebatteriesifthemonitorisnottobeusedforamonthormoretoavoid
damagefrombatteryleakage.
Set clock and date
• Onceyouinstallthebatteryorturnothemonitor,itwill
enterclockmodeandtheLCDalternatesbetweentime
anddate.Fig.1
• Whilethemonitorisinclockmode,pressboththeSTART
andMEMbuttonssimultaneouslyandthenumberformonth
willash.WhilethenumberisashingpresstheMEMbutton
tochangethenumber.PresstheSTARTbuttontomovetothe
numberfortheday.Whilethenumberisashingpressthe
MEMbuttontochangethenumbers.Repeatthisprocedurefor
thehourandminutes.
• Whiletheminutenumberisblinking,presstheSTARTbutton
toconrm.
• Onceyouchangethebatteries,youshouldcheckandreadjust
thetimeanddate.
4
2
3
Fig.1