Installation manual
E L A N H O M E S Y S T E M S
© ELAN Home Systems 2009 • All rights reserved. Page 5
A12 INSTALLATION MANUAL
Multi-Room Applications
The A12 is specifically designed for multi-room applications. Virtually every feature was selected to enhance the
multi-room experience and simplify the multi-room installation. With Buffered Loop Outputs, Bus Modes, and
advanced Trigger options, the A12 can be customized for even the most complex systems.
Independent Stereo Zones
The A12 is designed to easily power six independent stereo zones without any special setup procedures. This is the
standard configuration for most multi-zone audio distribution systems. In the drawing below, each pair of speakers
will have independent line-level volume control.
Three Independent Stereo Zones
• Zone 1 Output to Line Inputs 1 & 2
• Zone 2 Output to Line Inputs 3 & 4
• Zone 3 Output to Line Inputs 5 & 6
• Bus Mode DIP Switches in Default DIRECT Position
Each Zone’s Speakers Volume Ramps Up & Down Independently
A6
RL
Wide Coverage Zone
Set A6
BUS MODE
Button
To ON
Bus Mode Button
Line Level
Analog Audio
Output
Figure 2-2: Independent Stereo Zones