Specifications
2-24 
 ELMo 120 Multiplexer installation and testin
g
Revision 2.01 ELMo 120 Multiplexer Installation and Maintenance Guide   08-01023-01
Testing the ELMo 120 Multiplexer installation
Testing an ELMo 120 Multiplexer installation in an EtherLoop system 
includes the following tasks: 
• Testing voice connectivity (see page 2-27)
• Testing data connectivity (see page 2-28)
• EtherLoop end-to-end testing (see page 2-29)
The following sections contain testing-related information followed by the 
ELMo 120 Multiplexer testing tasks. Testing tasks for network support 
equipment such as LAN/WAN routers are not included in this document. 
ELMo 120 testing locations
Primary test points for an EtherLoop installation include the following:
• customer premise cross-connect containing the connections for the ELMo 
120 Multiplexer and customer premise equipment
• Elite modem user rooms
If the system is having trouble, other test points may be required.
ELMo 120 test point diagrams
Figure 2-16 on page 2-25 shows the schematic layout and primary test points 
of an ELMo 120 voice/data system. Figure 2-17 on page 2-26 shows the 
schematic layout and primary test points of an ELMo 120 data-only system.