FOCUS SPOT 250R Elation Professional 4295 Charter Street Los Angeles, Ca 90058 www.elationlighting.
Focus Spot 250R™ ©Elation Professional® 2 Focus Spot 250R™
Focus Spot 250R™ Contents 1. General Information……………………………………………………… 3 a. Introduction…………………………………………………………. 3 b. Unpacking………………………………………………………..…. 3 c. Customer Support…………………………………………….……. 3 d. Warranty Registration……………………………………………… 4 e. Discharge Lamp Warning…………………………………………. 4 2. Safety Instructions……………………………………………………….. 6 3. Features…………………………………………………………………… 8 4. General Guidelines………………………………………………………. 9 5. Lamp Installation…………………………………………………………. 10 a. Lamp installation…………………………………………………….
Focus Spot 250R™ 1. General Information INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The Focus Spot 250R™, has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
Focus Spot 250R™ WARRANTY REGISTRATION: The Focus Spot 250R™ carries a two year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A.
Focus Spot 250R™ Extreme caution should be used when operated this or any fixture fitted with a gas discharge lamp. Never open this fixture while in use! During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time. This device falls under protection-class I.
Focus Spot 250R™ 2. Safety Instructions The Focus Spot 250™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked.
Focus Spot 250R™ 11. Do not attempt to operate this fixture if the power cord has become damaged or frayed. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims. Never touch the device during operation! The housing may heat up Never look directly into the light source, as sensitive persons may suffer an epileptic shock.
Focus Spot 250R™ 3.
Focus Spot 250R™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect for designed for use on stage, in nightclubs, in theatres, etc. Do not attempt operation or installation without a proper knowledge on how to so. This fixture was designed for indoor use only. Consistent operational breaks may ensure that the fixture will function properly for may years to come. Do not shake the fixture around. Avoid brute force when installing or operating the device.
Focus Spot 250R™ 5. LAMP INSTALLATION INSTRUCTIONS Installing or replacing the lamp Only install the lamp with the device unplugged from the mains. The lamp has to be replaced when it is damaged or deformed. Before replacing the lamp be sure the unit has ample time to cool, to avoid injury to yourself never touch the lamp when it is hot. During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.
Focus Spot 250R™ Lamp Optimization The lamp orientation and optimization must be adjusted after every lamp change. This procedure centers the lamp in the reflector. Proper optimization will increase lamp life and ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a lower deviation can cause damage to the lamp and/or lens.
Focus Spot 250R™ 6. Mounting and Installation Mounting The FOCUS SPOT 250R™ is fully operational in three different mounting positions, hanging upside-down from a ceiling, side mounted, or set on a flat level surface (see illustration below). Be sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage in the event of a clamp failure (see section “b” on the next page).
Focus Spot 250R™ installation. Never use the carrying handles for secondary attachment. a) Cam lock System: This system allows a quick and efficient means to secure a clamp to the unit. To secure a clamp to the unit, attach a clamp that is rated to handle the weight of the unit to your cam lock. After a clamp has been attached to the cam lock, attach the cam lock to the designated position on the bottom of your unit. Lock the cam lock into position by turning the wing nuts 90°.
Focus Spot 250R™ 7. Understanding DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below). If you are constructing your own cables be sure to use two conductor shielded digital cable rated at a 120 ohms (this cable can be purchased at almost all professional sound and lighting stores).
Focus Spot 250R™ DMX-512 connection with DMX terminator When longer runs of cable are used, you may need to use a terminator on the last fixture to avoid erratic behavior. A terminator is a 90-120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line.
Focus Spot 250R™ Fixture DMX address; All fixtures should be given a DMX starting address when using a DMX signal, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the base of the device.
Focus Spot 250R™ signal the display will flash "A.XXX" (XXX representing the actual DMX address). If your fixture is connected to a DMX controller and the display is flashing (not receiving a DMX signal), please check the following: - The 3 PIN XLR plug (cable with DMX signal from controller) is not connected or is not inserted completely into the DMX input jack. - The DMX controller is switched off or defective. - The DMX cable or connector is defective.
Focus Spot 250R™ 8. FIXTURE MENU On-Board System Menu: The FOCUS SPOT 250R™ comes with an easy to navigate system menu. This next section will detail the functions of each command in the system menu. Control Board: The control panel located on the top of the fixture allows you to access the main menu and make all necessary adjustments to the Focus Spot 250R™. During normal operation, tapping the “MODE” key once will access the fixture’s main menu.
Focus Spot 250R™ 5 RESE ALL Reset all motors and returns fixture to home Reset only motors for pan/tilt Reset only motors for colors SCAN COLR GOBO Reset only motors for gobo and rotation Reset only motors for shutter and/or dimmer Reset other motors Displays the total fixture running time Displays a lamps running time SHTR 6 7 8 9 10 11 12 TIME RPAN RTLT FINE DEGR MIC DISP 13 SPEC 14 EDIT OTHR LIFE 0000~9999 LAMP 0000~9999 CLMP ON/OFF ON/OFF ON/OFF 630/540 M-XX M-70 VALU D–XX D-00 (DXXX)
Focus Spot 250R™ Main Menu Functions 1. ADDRESS MENU - AOO1 - A511 (Value) - This is where you set the fixtures DMX address. Setting/Changing the DMX Address After applying power to the FOCUS SPOT 250R™ the LED will display the fixture’s current DMX address immediately after the reset sequence. If the fixture is not receiving a DMX signal the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1. Switch on the FOCUS SPOT 250R™ finished.
Focus Spot 250R™ channels. For example: If you press the up button until “T-03” is displayed, the unit will test the color channel, changing the color one by one and show the rainbow effect with different speeds. There are 11 channels, but only channels 1, 3, 5, 6, 8, and 9 can be tested. 4. Press MODE/ENTER or EXIT to exit. 3. PLAY MENU - RUN – This feature is used to run the internal preset programs as either a Master or Slave (ALON) unit.
Focus Spot 250R™ 5. Press Mode/Esc to return to the main menu. 4. LAMP MENU ON/OFF Manually switches the lamp on and off. LAMP MENU LAMP – This menu function will manually turn the lamp on and off. 1. Access the main menu. 2. Tap the UP button until“LAMP”is displayed, press ENTER. 3. The display will show“ON/OFF”. 4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this function. 5. Press ENTER to confirm. 6. Press MODE/ESC to return to the main menu. 5.
Focus Spot 250R™ mirror motor. 1. Access the main menu. 2. Tap the UP button until “RESE” is displayed, press ENTER. 3. Tap the UP button until “SCAN” is displayed, press ENTER to confirm. 4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the color motor. Press ENTER. 5. Press MODE/ESC to return to the main menu. COLR - When you activate this reset function, the fixture will only reset the color wheel motor. 1. Access the main menu. 2.
Focus Spot 250R™ 6. TIME MENU - LIFE - Displays the fixtures total running time. LAMP - Displays the lamp running time. CLMP - Clears the lamp running time. TIME MAIN MENU LIFE - With this function you can display the total running time of the unit. 1. Access the main menu. 2. Tap the UP button until“TIME”is displayed, press ENTER. 3. Tap the UP button until“LIFE”is displayed, press ENTER. 4. Press MODE/ESC to return to the main menu.
Focus Spot 250R™ This menu setting reverses the Pan movements. RPAN MENU - RPAN – This menu function will reverse the mirror PAN movements. 1. Access the main menu. 2. Tap the UP button until“RPAN”is displayed, press ENTER. 3. The display will show“ON/OFF”. 4. Press the UP button to select “O N ” to activate this function, or “ O F F ” to deactivate this function. 5. Press ENTER to confirm. 6. Press MODE/ESC to return to the main menu. 8. RTLT MENU This menu setting reverses the Tilt movements.
Focus Spot 250R™ 16bit mode the unit will have 11 DMX channels that includes two pan movement channels and two tilt movement channels. In 8bit mode the fixture will only have one pan and one tilt movement channel for a total of nine DMX channels. 1. Access the main menu. 2. Tap the UP button until“FINE”is displayed, press ENTER. 3. The display will show“ON/OFF”. 4. Press the UP button to select “O N ” to activate this function, or “ O F F ” to deactivate this function. 5. Press ENTER to confirm. 6.
Focus Spot 250R™ 12. DISPLAY MENU - VALU (DMX-512 Value) - Display the DMX-512 value of each channel. D ON (Display On) – Turns the digital display on or off. FLIP - “Flips” the digital display 180 degrees. DISP MENU - This menu function will control the various on-board display features. VALU – This function will display the DMX value of each channel as it is adjusted through the use of a DMX console. 1. Access the main menu. 2. Tap the UP button until “DISP” is displayed. 3.
Focus Spot 250R™ 5. Press the UP button to select “O N ” to activate this function, or “ O F F ” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. 13. SPEC MENU – LAAU - Automatic lamp start with power. EBOC - Allows DMX address to be changed via and external DMX controller. DLOF - Switch lamp via DMX controller. DLAY - Lamp delay on time. SPOT - This provides a spot beam for better lamp optimization. DFSE (Default) - Resets the unit to default.
Focus Spot 250R™ 3. Tap the UP button until “RDMX” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255.
Focus Spot 250R™ 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “DLAY” is displayed, press ENTER. 4. The display will show “D-XX.” 5. Press the UP and DOWN buttons to adjust the delay time. 6. When completed press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. SPOT – This function allows you to optimize the lamp without the use of an external DMX controller. In this mode, the device will not react to any control signal. 1. Access the main menu. 2.
Focus Spot 250R™ 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “FEED” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. VER - Use this function to display the Software version of the unit. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3.
Focus Spot 250R™ number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit. 1. Access the main menu. 2. Tap the UP button until “EDIT” is displayed, press ENTER. 3. Tap the UP button until “RUN” is displayed, press ENTER. 4. “AUTO”is displayed. If you press the UP button it will show “S O U N ”. Select which one you want to activate, and press ENTER. 5. Press UP, to select “ALON” or “NAST”. Which mean stand alone, and master/slave mode. 6.
Focus Spot 250R™ 2. Tap the UP button until “EDIT” is displayed and press ENTER. 3. The display will show “SC-01” , this stands for the scene number. For example, “SC-01” is displayed, it means you will be editing scene 1, press ENTER. You can change the scene number by tapping the UP button. 4. Press ENTER, the display will show “C-01,” this represents the channel number. If “C-01” is displayed, you will be editing the fixture’s channel 1 value of the selected scene, press ENTER.
Focus Spot 250R™ 3. Press [MODE/ESC], the display shows “SC01”. 4. Press [MODE/ESC], the display shows “C-01”. 5. Select "CEDT" by pressing [UP] or [DN]. 6. Press [MODE/ESC], the display shows "OFF". 7. Press [UP], the display shows "ON". 8. Press [MODE/ESC], the display shows "SC02". You successfully downloaded the first scene. 9. Adjust the Step-time as described above. 10. Call up the second scene in your controller now. 11. Repeat steps 5-11 until all desired scenes are downloaded. 12.
Focus Spot 250R™ 9. DMX Channel Traits: The chart below details the channel layout for 11 DMX channels (default). In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the fixture into a 9 channel DMX fixture. CHANNEL 1: Pan movement (max. 630°) CHANNEL 2: 16 bit pan movement (pan fine) CHANNEL 3: Tilt movement (max.
Focus Spot 250R™ DMX channel function and values: Channel 1 – PAN Coarse 8bit : Channel 2 – PAN Fine 16bit Channel 3 – TILT Coarse 8bit Channel 4 – TILT Fine 16bit Channel 5 - Color Wheel : 0-13 Open (White) 14-27 RED 28-41 BLUE 42-55 GREEN 56-69 YELLOW 70-83 MAGENTA 84-97 ORANGE 98-111 PURPLE 112-128 PINK 128-187 Clockwise Color Scroll (fast to slow) 188-193 No Rotation 194-255 Counter-Clockwise Color Scroll (slow to fast) Channel 6 - Gobo 0-9 Open 10-19 Gobo 1 20-29 Gobo 2 30-39 Gobo 3 40-49 Gobo 4 50-59
Focus Spot 250R™ Channel 8 - Shutter, Strobe: 0-31 Shutter Closed 32-63 Dimmer (close to open) 64-95 Strobe Effect (slow to fast) 96-127 No function (shutter open) 128-159 Pulse-effect in sequences 160-191 No function (shutter open) 192-223 Random strobe effect slow to fast 224-255 No function (shutter open) Channel 9 - Focus 0-255 Continuous adjustment from near to far Channel 10 – Pan/Tilt Motor Speed 0-4 Max speed 5-225 Max to min speed 226-235 Blackout by movement 236-245 Blackout by all wheel changing
Focus Spot 250R™ 10. ERROR CODES: When power is applied, the unit will automatically enter a “reset/test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “02Er,” it means there is some type of error with the channel 2 motor.
Focus Spot 250R™ 05Er - Color-wheel error: The color wheel is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Focus Spot 250R™ 11. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1. All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded. 2. There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing). 3. Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances. 4.
Focus Spot 250R™ 12. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
Focus Spot 250R™ E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
Focus Spot 250R™ 13. TECHNICAL SPECIFICATIONS Power supply (user selectable): _98VAC,50Hz;_120VAC,50Hz;_208VAC,50Hz; _220VAC,50Hz;_230VAC,50Hz;_240VAC,50Hz; or _98VAC, 60Hz;_120VAC,60Hz;_208VAC,60Hz; _220VAC,60Hz;_230VAC,60Hz;_240VAC,60Hz; Power consumption: max. 400W: Lamp: MSD250 GY9.5 socket, Metal Halide (250w, 8500˚K, 3000hrs) Fuse: GMA 250v/8A Motors: 7 micro motors Pan Movement: 630˚ in 3.5 sec. (default) 540˚ (user selectable) Tilt Movement: 265˚ in 2.0 sec.
Focus Spot 250R™ Photometric Data: Gobos: Dimensional Drawings: ©Elation Professional® 45 Focus Spot 250R™
Focus Spot 250R™ ©Elation Professional® 46 Focus Spot 250R™
Focus Spot 250R™ ©Elation Professional® 47 Focus Spot 250R™
Focus Spot 250R™ Elation Professional 4295 Charter Street Los Angeles, CA. 90058 323-582-3322 / 323-582-3108 fax www.ElationLighting.com / info@ElationLighitng.