ELAR 108PAR RGBW Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev. 01/08/2010 – visage Version 1.
ELAR 108PAR RGBW™ ©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.
ELAR 108PAR RGBW™ TABLE OF CONTENS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 3 2. Safety Instructions………………………………………………………........…………. 5 3. Features……………………………………………………………………………………7 4. General Guidelines………………………………………………………………………. 8 5. Fixture Overview…………………………………………………………………………. 9 6.
ELAR 108PAR RGBW™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The ELAR 108PAR RGBW™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
ELAR 108PAR RGBW™ yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The ELAR 108PAR RGBW™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A.
ELAR 108PAR RGBW™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling.
ELAR 108PAR RGBW™ replace it immediately with a new one of similar power rating. 12. Always disconnect from main power before performing any type of service or any cleaning procedure. 13. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 14. Please be aware that damages caused by modifications to the device are not subject to warranty.
ELAR 108PAR RGBW™ 3.
ELAR 108PAR RGBW™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. Consistent operational breaks will ensure that the fixture will function properly for many years to come. Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
ELAR 108PAR RGBW™ 5. FIXTURE OVERVIEW ©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.
ELAR 108PAR RGBW™ 1. LED Lens Assembly – The lens assembly may be user replaced in the event repair is needed or a different beam angle is required. 2. LED Display – 4-segment menu display. Used to display the DMX address as well as all other menu functions. 3. Power Output Lead – This lead is used to jump power to another ELAR 108PAR RGBW™. Please do not daisy chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables. 4.
ELAR 108PAR RGBW™ cable that converts a standard Edison 3-prong to the IP rated twist lock connector. When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating. 11. DMX In Lead – This lead is the main DMX input lead.
ELAR 108PAR RGBW™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
ELAR 108PAR RGBW™ Mounting The ELAR 108PAR RGBW™ is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
ELAR 108PAR RGBW™ When mounting this fixture to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an added safety measure be sure to attach at least one properly rated safety cable to the fixture. See illustrations below. Securing the ELAR 108PAR RGBW™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means.
ELAR 108PAR RGBW™ 7. UNDERSTANDING DMX DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
ELAR 108PAR RGBW™ “First” Power Cable – A special power “First” cable is included with every fixture. This cables is used to provide power to your fixture. This cable comes with the IP rated twist lock connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be sure to only use this cable for power distribution and never attempt to connect this cable to the DMX lines. You can chain multiple fixtures together through serial linking.
ELAR 108PAR RGBW™ 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The following chart details a proper cable conversion.
ELAR 108PAR RGBW™ set the starting DMX address of the first unit to 1, the second unit to 10 (9 + 1), the third unit to 19 (9 + 10), and so on. Note: During start-up the ELAR 108PAR RGBW™ will automatically detect whether a DMX data signal is being received or not. If a DMX data signal is being received, the display will show "A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX signal the display will flash "A.XXX" (XXX representing the actual DMX address).
ELAR 108PAR RGBW™ 8. DISPLAY LED INDICATOR. The ELAR 108PAR RGBW ™ has a LED indicator on the display. This indicator is designed to give a quick visual indication of the fixtures’ DMX status. The illustration below details the functionality of the LED indicators. The LED indicator represents DMX signal: • If the indicators is on, a clean DMX signal is present • If the indicator is off, there is no DMX signal present ©Elation Professional, Los Angeles Ca. 19 www.ElationLighting.
ELAR 108PAR RGBW™ 9. DISPLAY MENU Default settings shaded. MODE SET MANL TIME EDIT ~ ~ VALU SLAV RDMX AUTO VALU FLIP D ON 4CH/5CH/7CH/9CH OFF/HOLD/AUTO ON/OFF V-1.0~V-9.
ELAR 108PAR RGBW™ in a daisy-chain fashion it is imperative to assign a proper and unique starting DMX address to each and every fixture. The DMX address is non-destructive and will remain in the fixture’s memory even when the power to the unit is switched off. Memory is backed-up and retain by an internal power source that should last about five years. For proper DMX addressing see “DMX Addressing” on page 25 of this user manual.
ELAR 108PAR RGBW™ 9.1.3 - Menu Display Settings This function allows the internal programs to run in either stand-alone or master/salve DMX chain. In “Alone” mode “VALU” - Display the DMX 512 value of each channel This function will electronically display the current DMX value for any channel that is currently being adjusted. The display will automatically detail the changing DMX values as they are received from the controller. This function is “off” by default.
ELAR 108PAR RGBW™ - Restore Default This function is used to restore the factory settings of the device. All settings will be set back to the default values (shaded). Any edited scenes will be lost. Software Version This function will display the current firmware version. 9.3 “MANL” – Manual Fixture Settings: This function allows the each of the nine DMX channels to be controlled manually.
ELAR 108PAR RGBW™ controller. For detailed instructions on how to complete this task please see “Working with Built-In Programs” Section 12/ Page 35. 9.5.1 Select program – This function allows the user to select one of ten of the user defined built-in programs. This program is then accessed in “Function Mode” under “Program Run.” 9.5.2 Edit program – This function allows the user to edit the built-in programs. 9.5.
ELAR 108PAR RGBW™ 10. DMX ADDRESSING Setting the DMX address - After the fixture is turned “ON” it will immediately complete a reset process that test all the fixture’s functions. When the reset process concludes the LCD will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1.
ELAR 108PAR RGBW™ 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511. 3. Use channel 3 to set your desired DMX starting address.
ELAR 108PAR RGBW™ 11. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off. DMX CHANNEL TRAITS The charts below and on the preceding pages outline the different DMX traits for the three different DMX modes.
ELAR 108PAR RGBW™ DMX channel’s functions and their values (4-Channel Mode): Channel 1 0-255 - Red: Red (0-Black, 255 - 100% Red) Channel 2 0-255 - Green: Green (0-Black, 255 - 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255 - 100% Blue) Channel 4 - White: 0-255 White (0-Black, 255 - 100% White) 5-Channel mode: In this mode channel one controls all the red LEDs, channel two controls all the green LEDs, channels three controls all the blue LEDs, channels four controls all the white LEDs, and chan
ELAR 108PAR RGBW™ DMX channel’s functions and their values (5-Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255 - 100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255 - 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255 - 100% Blue) Channel 4 - White: 0-255 White (0-Black, 255 - 100% White) Channel 5 - General dimming 0-255 Dimming (0-Black, 255- 100%) 7-Channel mode: In this mode channels 1~4 are used to control the RGBW LEDs and channels 5~7 will control special features.
ELAR 108PAR RGBW™ DMX channel’s functions and their values (7-Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255- 100% Blue) Channel 4 - White: 0-255 White (0-Black, 255- 100% White) Channel 5 - Color Temperature: 0 No function 1~255 Color Temperature (2700K-7200K) Channel 6 - Color macros: 0 No function 1-7 R02 Bastard Amber 8-15 R04 Medium Amber 16-23 R09 Pale Amber Gold 24-31 R316 Gallo Go
ELAR 108PAR RGBW™ 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 R67 Light Sky Blue R68 Sky Blue R69 Brilliant Blue R76 Light Green Blue R79 Bright Blue R80 Primary Blue R382 Congo Blue R87 Pale Yellow Green R89 Moss Green R91 Primary Green L200 Double CTB L201 Full CTB L202 1/2 CTB L119 Dark Blue White Channel 7 - General dimming/speed: 0-255 Dimming (0-Black, 255- 100%) Speed from slow to fast - when running internal programs Spee
ELAR 108PAR RGBW™ DMX channel’s functions and their values (9-Channel Mode): Channel 1 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 2 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channel 3 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 4 - White LED: 0-255 White (0-Black, 255-100% White) Channel 5 - Color Temperature: 0 1-255 No function Color Temperature (2700K-7200K) Channel 6 - Color Macros: 0 1-7 No function R02 Bastard Amber ©Elation Professional, Los Angeles Ca.
ELAR 108PAR RGBW™ 8-15 16-23 24-31 32-39 40-47 48-55 56-63 64-71 72-79 80-87 88-95 96-103 104-111 112-119 120-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 R04 Medium Amber R09 Pale Amber Gold R316 Gallo Gold R21 Golden Amber R26 Light Red R27 Medium Red R36 Medium Pink R339 Broadway Pink R344 Follies Pink R52 Light Lavender R54 Special Lavender R57 Lavender R59 Indigo R361 Hemsley Blue R362 Tipton Blue R64 Light Steel B
ELAR 108PAR RGBW™ 71-100 101-130 131-160 161-190 191-220 221-255 Internal program 3 Internal program 4 Internal program 5 Internal program 6 Internal program 7 Gradient effect Channel 8 - Shutter, strobe: 0-31 Blackout (All LEDs Off) 32-63 Open (LEDs Active) 64-95 Strobe effect slow to fast 96-127 Open (LEDs Active) 128-159 Pulse-effect in sequences 160-191 Open (LEDs Active) 192-223 Random strobe effect slow to fast 224-255 Open (LEDs Active) Channel 9 - General dimming/speed: 0-255 Dimming (0-Black, 2
ELAR 108PAR RGBW™ 12. WORKING WITH BUILT-IN PROGRAMS The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. The following instructions will detail the procedures for using the on-board system menu as well as using a DMX compliant controller.
ELAR 108PAR RGBW™ lock the value into the scenes memory. You can repeat the procedure for all functions listed below: - “Auto Program” – Allows access to all of the fixture’s DMX traits.
ELAR 108PAR RGBW™ “DOWN” buttons to toggle through the scenes created in “Step 1.” Press the “ENTER” button to add a scene to the program. Tapping the “Enter” button will automatically lock the selected scene into the programs’ memory. Repeat the process until all the desired scenes have been added to the program. Each program can store a maximum of 64 scenes. • To test the program access “Program Test” in the “Program Edit” menu function.
ELAR 108PAR RGBW™ 13. LENS REPLACEMENT The ELAR 108PAR RGBW comes with a removable front cover that allows the lens assembly to be changed out to achieve different beam angles. Lens cover is held in place by two ¼ turn locking fasteners. To remove the cover; 1) Turn the locking fasteners in a counter-clockwise direction. 2) Once the fasteners are loose lift the cover straight up to expose the inner lens (see illustration below). 3) Locate the 8 securing screws on the inner cover and remove them.
ELAR 108PAR RGBW™ 14. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
ELAR 108PAR RGBW™ 15. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
ELAR 108PAR RGBW™ effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
ELAR 108PAR RGBW™ 16. PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. 42 www.ElationLighting.
ELAR 108PAR RGBW™ 17. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 43 www.ElationLighting.
ELAR 108PAR RGBW™ 18. CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. 44 www.ElationLighting.
ELAR 108PAR RGBW™ 19. TECHNICAL SPECIFICATIONS Power supply: 100v~240v / 50Hz~60Hz AC Power consumption: Maximum 120w IP Grade: IP65 LED Configuration: 36 x 3 Watt (12 x Red, 9 x Green, 9 x Blue, 6 x White) IP Rating: IP65 Weight: 6 Kgs / 15.2Lbs DMX Channels: 9, 7, 5, or 4 (default) Channel mode DMX Drive: Standard DMX-512, 3 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
ELAR 108PAR RGBW™ ©Elation Professional, Los Angeles Ca. 46 www.ElationLighting.
Elation Professional 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighitng.com Rev. 01/08/2010 – visage Version 1.