™ ELAR 216 Panel Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev. 5/25/2010 – visage Version 1.
ELAR 216 Panel™ ©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.
ELAR 216 Panel™ TABLE OF CONTENS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 3 2. Safety Instructions………………………………………………………........…………. 5 3. Features……………………………………………………………………………………7 4. General Guidelines………………………………………………………………………. 8 5. Fixture Overview…………………………………………………………………………. 9 6.
ELAR 216 Panel™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The ELAR 216 Panel ™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
ELAR 216 Panel™ Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The ELAR 216 Panel™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase.
ELAR 216 Panel™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling. See page 12.
ELAR 216 Panel™ 12. Always disconnect from main power before performing any type of service or any cleaning procedure. 13. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 14. Please be aware that damages caused by modifications to the device are not subject to warranty. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims.
ELAR 216 Panel™ 3.
ELAR 216 Panel™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. Consistent operational breaks will ensure that the fixture will function properly for many years to come. Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
ELAR 216 Panel™ 5. FIXTURE OVERVIEW ©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.
ELAR 216 Panel™ 1. Yoke Assembly – This yoke is designed to perform two functions; 1) When split it can be used as a floor stand bracket. 2) Used to secure a mounting clamp for truss mounting. 2. LED Lens Assembly – The lens assembly may be user replaced in the event repair is needed or a different beam angle is required. 3. DMX In Lead – This lead is the main DMX input lead.
ELAR 216 Panel™ 10. Power Output Lead – This lead is used to jump power to another ELAR 216 Panel™. Please do not daisy chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables. 11. Main Power Input Lead – This lead is the main power input lead. When the unit is the first in a chain or the only fixture to be used, be sure to use the power starter cable that converts a standard Edison 3-prong to the IP rated twist lock connector.
ELAR 216 Panel™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
ELAR 216 Panel™ Mounting The ELAR 216 Panel ™ is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
ELAR 216 Panel™ added safety measure be sure to attach at least one properly rated safety cable to the fixture. See illustrations below. Securing the ELAR 216 Panel ™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means. The fixture provides a built-in rigging point for a safety cable as illustrated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to the hanging bracket.
ELAR 216 Panel™ 7. UNDERSTANDING DMX DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
ELAR 216 Panel™ “First” Power Cable – A special power “First” cable is included with every fixture. This cables is used to provide power to your fixture. This cable comes with the IP rated twist lock connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be sure to only use this cable for power distribution and never attempt to connect this cable to the DMX lines. You can chain multiple fixtures together through serial linking.
ELAR 216 Panel™ 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The following chart details a proper cable conversion.
ELAR 216 Panel™ In the case of the ELAR 216 Panel ™, which is up to a nine channel fixture, you should set the starting DMX address of the first unit to 1, the second unit to 10 (9 + 1), the third unit to 19 (9 + 10), and so on. Note: During start-up the ELAR 216 Panel ™ will automatically detect whether a DMX data signal is being received or not. If a DMX data signal is being received, the display will show "A.XXX" (XXX representing the actual DMX address).
ELAR 216 Panel™ 8. DISPLAY LED INDICATOR. The ELAR 216 Panel ™ has a LED indicator on the display. This indicator is designed to give a quick visual indication of the fixtures’ DMX status. The illustration below details the functionality of the LED indicators. The LED indicator represents DMX signal: • If the indicators is on, a clean DMX signal is present • If the indicator is off, there is no DMX signal present ©Elation Professional, Los Angeles Ca. 19 www.ElationLighting.
ELAR 216 Panel™ 9. DISPLAY MENU Function Mode Default settings shaded.
ELAR 216 Panel™ Edit Program Edit Scenes Rec. Controller Program 1 : Program 10 Edit Scene 001 ~ Edit Scene 250 XX~XX Program Test Step 01=SCxxx Step 64=SCxxx Red,…… --Secne Time-Input By Outside (“STEP XX”) Red=xxx…… TIME=xx.xs Testing program Program in loop Save and exit Save and automatically return manual scenes edit Scenes via External DMX Controller Remarks: 1) If the fixture does not receive a DMX signal the menu display will flash repeatedly. 9.
ELAR 216 Panel™ without a controller. “Auto Program”” – Auto Program Mode This function allows the internal programs to run in either stand-alone or master/salve mode. In “Master” mode the fixture will send command data to all other fixtures connect via the DMX chain. In “Alone” mode the fixture will operate as a single fixture. The program for this mode is selected in the “Select program” section of the control menu. You can set the number of steps under “Edit program”.
ELAR 216 Panel™ Clear Last Run This function resets the lamp “ON” time to zero. Please reset the lamp “ON” time at every lamp replacement. This procedure tracks the lamp running time so the lamp can be replaced at the end of it’s recommended duty cycle. • Select “Clear lamp time” in the system menu. • The LCD will display “ON” or “OFF.” Were “ON” will reset the lamp time. • Press enter to confirm. • Press the Mode/Esc-button to return to the main menu. Temperature Info.
ELAR 216 Panel™ without any DMX signal, the fixture will automatically go in to sound-active mode. Available settings are: “Close” – Shutter flags will close. “Hold” – Fixture will remain at it’s last settings. “Auto” – Fixture will go into stand-alone mode, running the built-in program. “Music” – The fixture will go into sound-active mode. Display Settings – The display is designed to turn off during normal operation to avoid excessive light in situations that require an extremely dark environment.
ELAR 216 Panel™ 9.6 “Edit” Internal Program Settings: The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. For detailed instructions on how to complete this task please see “Working with Built-In Programs” Section 12/ Page 31.
ELAR 216 Panel™ 10. DMX ADDRESSING Setting the DMX address - After the fixture is turned “ON” it will immediately complete a reset process that test all the fixture’s functions. When the reset process concludes the LCD will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1.
ELAR 216 Panel™ 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511. 3. Use channel 3 to set your desired DMX starting address.
ELAR 216 Panel™ 11. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off. DMX CHANNEL TRAITS The chart below and on the preceding pages outlines the different DMX traits for the four different DMX modes.
ELAR 216 Panel™ 64-71 72-79 80-87 88-95 96-103 104-111 112-119 120-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 NA NA NA 7 NA NA NA 8 0-10 11-40 41-70 71-100 101-130 131-160 161-190 191-220 221-255 0-31 32-63 64-95 96-127 128-159 160-191 ©Elation Professional, Los Angeles Ca.
ELAR 216 Panel™ NA 5 7 9 192-223 Random strobe effect slow to fast 224-255 Shutter Open (LEDs may be used) General dimming/speed: 0-255 Dimming (0 - LEDs Off, 255 - 100%) Speed from slow to fast /when running internal programs Speed from slow to fast when running gradient effect ©Elation Professional, Los Angeles Ca. 30 www.ElationLighting.
ELAR 216 Panel™ 12. WORKING WITH BUILT-IN PROGRAMS The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. The following instructions will detail the procedures for using the on-board system menu as well as using a DMX compliant controller.
ELAR 216 Panel™ lock the value into the scenes memory. You can repeat the procedure for all functions listed below: - “Auto Program” – Allows access to all of the fixture’s DMX traits.
ELAR 216 Panel™ “DOWN” buttons to toggle through the scenes created in “Step 1.” Press the “ENTER” button to add a scene to the program. Tapping the “Enter” button will automatically lock the selected scene into the programs’ memory. Repeat the process until all the desired scenes have been added to the program. Each program can store a maximum of 64 scenes. • To test the program access “Program Test” in the “Program Edit” menu function.
ELAR 216 Panel™ 13. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
ELAR 216 Panel™ 14. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 35 www.ElationLighting.
ELAR 216 Panel™ 15. CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. 36 www.ElationLighting.
ELAR 216 Panel™ 16. PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. 37 www.ElationLighting.
ELAR 216 Panel™ 16. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
ELAR 216 Panel™ effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
ELAR 216 Panel™ 17. TECHNICAL SPECIFICATIONS Power supply: 100v~240v / 50Hz~60Hz AC Power consumption: Maximum250w LED Configuration: 72 x 3 Watt (18 x Red, 18 x Green, 18 x Blue, 18 x White) IP Rating: IP65 DMX Channels: 4, 5, 7, or 9 Channel mode DMX Drive: Standard DMX-512, 5 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.