Design LED 72MKII Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev.
DESIGN LED 72MKII™ TABLE OF CONTENS 1. General Information……………………………………………………………………… 2 a. Introduction………………………………………………………………………. 2 b. Unpacking………………………………………………………..…………..….. 2 c. Customer Support…………………………………………….………………… 2 d. Warranty Registration……………………………………………………..…… 3 2. Safety Instructions………………………………………………………........…………. 4 3. Features…………………………………………………………………………………… 6 4. General Guidelines………………………………………………………………………. 7 5. Fixture Overview…………………………………………………………………………. 8 6.
DESIGN LED 72MKII™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The Design LED 72MKII™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
DESIGN LED 72MKII™ yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The Design LED 72MKII™ carries a two year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A.
DESIGN LED 72MKII™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. This fixture has been specially designed for use outdoors.
DESIGN LED 72MKII™ 12. Be sure the power cord is never crimped or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating. 13. Always disconnect from main power before performing any type of service or any cleaning procedure. 14. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 15. Please be aware that damages caused by modifications to the device are not subject to warranty.
DESIGN LED 72MKII™ 3.
DESIGN LED 72MKII™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for outdoor architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. Consistent operational breaks will ensure that the fixture will function properly for many years to come. Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
DESIGN LED 72MKII™ 5. FIXTURE OVERVIEW ©Elation Professional, Los Angeles Ca. 8 www.ElationLighting.
DESIGN LED 72MKII™ 1. Yoke Assembly – This yoke is designed to perform two functions; 1) When split it can be used as a floor stand bracket. 2) Used to secure a mounting clamp for truss mounting. 2. LED Lens Assembly – The lens assembly may be user replaced in the event repair is needed or a different beam angle is required. 3. DMX In Lead – This lead is the main DMX input lead.
DESIGN LED 72MKII™ 10. Power Output Lead – This lead is used to jump power to another Design LED 72MKII™. Please do not daisy-chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables. 11. Main Power Input Lead – This lead is the main power input lead. When the unit is the first in a chain or the only fixture to be used, be sure to use the power starter cable that converts a standard Edison 3-prong to the IP rated twist lock connector.
DESIGN LED 72MKII™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
DESIGN LED 72MKII™ Mounting The Design LED 72MKII™ is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
DESIGN LED 72MKII™ When mounting this fixture to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an added safety measure be sure to attach at least one properly rated safety cable to the fixture. See illustrations below. Securing the Design LED 72MKII™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means.
DESIGN LED 72MKII™ 7. UNDERSTANDING DMX DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
DESIGN LED 72MKII™ “First” Power Cable – A special power “First” cable is included with every fixture. This cables is used to provide power to your fixture. This cable comes with the IP rated twist lock connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be sure to only use this cable for power distribution and never attempt to connect this cable to the DMX lines. You can chain multiple fixtures together through serial linking.
DESIGN LED 72MKII™ 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The following chart details a proper cable conversion.
DESIGN LED 72MKII™ In the case of the Design LED 72MKII™, which is capable of controlling up to 15 DMX channels, you should set the starting DMX address of the first unit to 1, the second unit to 16 (15 + 1), the third unit to 31 (15 + 16), and so on. Note: During start-up the Design LED 72MKII™ will automatically detect whether a DMX data signal is being received or not. If a DMX data signal is being received, the display will show "A.XXX" (XXX representing the actual DMX address).
DESIGN LED 72MKII™ 8. DISPLAY LED INDICATORS. The Design LED 72MKII ™ has two LED indicators on the display. These indicators are designed to give a quick visual indication of the fixtures’ status. The illustration below details the functionality of the LED indicators. . . DMX OK . .
DESIGN LED 72MKII™ 9. MENU DMX MODE Default settings shaded.
DESIGN LED 72MKII™ NEW VALUE: 0-255 PRESET VALUE: XXX STROBE NEW VALUE: 0-255 PRESET VALUE: XXX SPEED CHASE 7 NEW VALUE: 0-256 PRESET VALUE: XXX FADE NEW VALUE: 0-256 PRESET VALUE: XXX STROBE NEW VALUE: 0-256 PRESET VALUE: XXX SPEED CHASE 8 NEW VALUE: 0-256 PRESET VALUE: XXX FADE NEW VALUE: 0-256 PRESET VALUE: XXX STROBE NEW VALUE: 0-256 PROGRAM SCENE BY EDIT SCENE # XX ON-BOARD CONTROLS EDIT/PLAY SET CHANNEL VALUE XXX DOWNLOAD SCENE SELECT SCENE # XX FROM CONTROLLER SA
DESIGN LED 72MKII™ 10. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off. DMX CHANNEL TRAITS The charts below and on the preceding pages outline the different DMX traits for the three different DMX modes.
DESIGN LED 72MKII™ 4-Channel mode: In this mode channel one controls all the red LEDs, channel two controls all the green LEDs, channels three controls all the blue LEDs, and channel four-- will control the master dimming level. CHANNEL 1:Red CHANNEL 2:Green CHANNEL 3:Blue CHANNEL 4:Dimmer/Speed 4-Channel Mode: The chart below details the DMX channel layout for 4-channel assignment.
DESIGN LED 72MKII™ 6-Channel mode: In this mode channels 1~3 are used to control the RGB LEDs and channels 4~6 will control special features. CHANNEL 1:Red CHANNEL 2:Green CHANNEL 3:Blue CHANNEL 4:Auto Programs (Built-in Programs) CHANNEL 5:Strobe CHANNEL 6:Dimmer/Speed 6-Channel Mode: The charts below and on the next page detail the DMX channel layout for 6-channel assignment.
DESIGN LED 72MKII™ Channel 2 0-255 - Green: Green (0-Black, 255- 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255- 100% Blue) Channel 4 - Internal programs: 0-10 No function 11-40 Internal program 1 41-70 Internal program 2 71-100 Internal program 3 101-130 Internal program 4 131-160 Internal program 5 161-190 Internal program 6 191-220 Internal program 7 221-255 Internal program 8 Channel 5 - Strobe: 0 No function 1~95 Strobe effect slow to fast 96-127 No function 128-1
DESIGN LED 72MKII™ 15-Channel mode: In this mode channels 1~12 are used to control the RGB LEDs and channels 13~15 will control special features.
DESIGN LED 72MKII™ Channel 3 - Blue: 0-255 Channel 4 0-255 Channel 5 0-255 Blue (0-Black, 255- 100% Blue) - Red: Red (0-Black, 255-100% Red) - Green: Green (0-Black, 255- 100% Green) Channel 6 - Blue: 0-255 Channel 7 0-255 Channel 8 0-255 Blue (0-Black, 255- 100% Blue) - Red: Red (0-Black, 255-100% Red) - Green: Green (0-Black, 255- 100% Green) Channel 9 - Blue: 0-255 Blue (0-Black, 255- 100% Blue) Channel 10 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 11 - Green: 0-255 Green (0-Black, 25
DESIGN LED 72MKII™ 101-130 Internal program 4 131-160 Internal program 5 161-190 Internal program 6 191-220 Internal program 7 221-255 Internal program 8 Channel 14 - Strobe: 0 No function 1~95 Strobe effect slow to fast 96-127 No function 128-159 Pulse effect in sequences 160-191 No function 192-223 Random strobe effect slow to fast 224-255 No function Channel 15 - General dimming / Program Speed Control This channel has two functions depending on the operating mode.
DESIGN LED 72MKII™ 11. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
DESIGN LED 72MKII™ 12. A. 2-YEAR LIMITED WARRANTY Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
DESIGN LED 72MKII™ effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
DESIGN LED 72MKII™ 13. PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. 31 www.ElationLighting.
DESIGN LED 72MKII™ 14. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 32 www.ElationLighting.
DESIGN LED 72MKII™ 15. CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. 33 www.ElationLighting.
DESIGN LED 72MKII™ 16. TECHNICAL SPECIFICATIONS Power supply: 100v~240v / 50Hz~60Hz AC Power consumption: Maximum 150w LED Configuration: 72 Luxeon K2, 3 Watts Each (24 x Red, 24 x Green 24 x Blue) IP Rating: IP65 Weight: 12 Kgs DMX Channels: 15, 6, 4, or 3 Channel mode DMX Drive: Standard DMX-512, 3 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
Elation Professional 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighitng.com Rev.