ELAR 180PAR RGBAW Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev. 4/26/2010 – visage Version 1.
ELAR 180 Par RGBAW™ ©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.
ELAR 180 Par RGBAW™ TABLE OF CONTENS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 3 2. Safety Instructions………………………………………………………........…………. 5 3. Features……………………………………………………………………………………7 4. General Guidelines………………………………………………………………………. 8 5. Fixture Overview…………………………………………………………………………. 9 6.
ELAR 180 Par RGBAW™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The ELAR 180 Par RGBAW™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
ELAR 180 Par RGBAW™ yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The ELAR 180 Par RGBAW™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A.
ELAR 180 Par RGBAW™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling.
ELAR 180 Par RGBAW™ replace it immediately with a new one of similar power rating. 12. Always disconnect from main power before performing any type of service or any cleaning procedure. 13. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 14. Please be aware that damages caused by modifications to the device are not subject to warranty.
ELAR 180 Par RGBAW™ 3.
ELAR 180 Par RGBAW™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. Consistent operational breaks will ensure that the fixture will function properly for many years to come. Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
ELAR 180 Par RGBAW™ 5. FIXTURE OVERVIEW ©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.
ELAR 180 Par RGBAW™ 1. LED Lens Assembly – The lens assembly may be user replaced in the event repair is needed or a different beam angle is required. 2. LED Display – 4-segment menu display. Used to display the DMX address as well as all other menu functions. 3. Power Output Lead – This lead is used to jump power to another ELAR 180 Par RGBAW™. Please do not daisy chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables. 4.
ELAR 180 Par RGBAW™ cable that converts a standard Edison 3-prong to the IP rated twist lock connector. When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating. 11. DMX In Lead – This lead is the main DMX input lead.
ELAR 180 Par RGBAW™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
ELAR 180 Par RGBAW™ Mounting The ELAR 180 Par RGBAW™ is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
ELAR 180 Par RGBAW™ When mounting this fixture to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an added safety measure be sure to attach at least one properly rated safety cable to the fixture. See illustrations below. Securing the ELAR 180 Par RGBAW™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means.
ELAR 180 Par RGBAW™ 7. UNDERSTANDING DMX DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
ELAR 180 Par RGBAW™ “First” Power Cable – A special power “First” cable is included with every fixture. This cables is used to provide power to your fixture. This cable comes with the IP rated twist lock connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be sure to only use this cable for power distribution and never attempt to connect this cable to the DMX lines. You can chain multiple fixtures together through serial linking.
ELAR 180 Par RGBAW™ 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The following chart details a proper cable conversion.
ELAR 180 Par RGBAW™ set the starting DMX address of the first unit to 1, the second unit to 11 (10 + 1), the third unit to 21 (10 + 11), and so on. Note: During start-up the ELAR 180 Par RGBAW™ will automatically detect whether a DMX data signal is being received or not. If a DMX data signal is being received, the display will show "A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX signal the display will flash "A.XXX" (XXX representing the actual DMX address).
ELAR 180 Par RGBAW™ 8. DISPLAY LED INDICATOR. The ELAR 180 Par RGBAW ™ has a LED indicator on the display. This indicator is designed to give a quick visual indication of the fixtures’ DMX status. The illustration below details the functionality of the LED indicators. The LED indicator represents DMX signal: • If the indicators is on, a clean DMX signal is present • If the indicator is off, there is no DMX signal present ©Elation Professional, Los Angeles Ca. 19 www.ElationLighting.
ELAR 180 Par RGBAW™ 9. DISPLAY MENU Default settings shaded. A001~AXXX VALU (AXXX) SLAV ON/OFF RDMX ON/OFF AUTO ALON/MAST VALU D-XX D-00(DXXX) MODE FLIP ON/OFF D ON ON/OFF SET POHO TIME EDIT ~ LOCK ON/OFF 5CH/6CH/8CH/10CH OFF/HOLD/AUTO ON/OFF MOD1/MODE2 ON/OFF V-1.0~V-9.
ELAR 180 Par RGBAW™ FADE TIME XXX XXX.X(000.1S~999. 9S) Remarks: 1) If the fixture does not receive a DMX signal the menu display will flash repeatedly. 2) TIME: Adjust the hold time for each scene in built-in chase programs. 3) FADE: Adjust the fade time between each scene in the built-in programs. 9.1 “MODE” - Function Mode: 9.1.1 - DMX address setting – This function is used to set or adjust the fixture’s starting DMX address.
ELAR 180 Par RGBAW™ “RDMX” - Address via DMX - This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and the fixture. RDMX is on by default. For operational instructions please see Section 10/Page 25 of this manual “Remote DMX addressing.” 9.1.2 - Internal Program Settings This function allows the internal programs to run in either stand-alone or master/salve mode.
ELAR 180 Par RGBAW™ LOCK –This function allows you to lock the keys. This function activates the automatic keylock command. If this function is activated, all menu keys will automatically lock whit in 15 seconds of the last menu function. To temporarily deactivate the keylock function, press and hold down the Mode/Esc-button for 3 seconds. 1. Access the main menu. 2. Tap the UP button until “DISP” is displayed. 3. Press ENTER, the display will show “VALU”. 4.
ELAR 180 Par RGBAW™ entertainment (rock and roll) use and Mode 2 is designed for theatrical use. Mode 1 has a quicker dimming curve and Mode 2 has a smoother dimming curve of 0-100%. - Power on to preserve the MANL settings This function is designed to work with the Manual (MANL) settings. When this function is turned on, all the manual settings will be retained after power has been shut off. Software Version This function will display the current firmware version. 9.
ELAR 180 Par RGBAW™ The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. For detailed instructions on how to complete this task please see “Working with Built-In Programs” Section 12/ Page 35. 9.5.
ELAR 180 Par RGBAW™ 10. DMX ADDRESSING Setting the DMX address - After the fixture is turned “ON” it will immediately complete a reset process that test all the fixture’s functions. When the reset process concludes the LCD will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1.
ELAR 180 Par RGBAW™ 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511. 3. Use channel 3 to set your desired DMX starting address.
ELAR 180 Par RGBAW™ 11. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off. DMX CHANNEL TRAITS The chart below and on the preceding pages outlines the different DMX traits for the four different DMX modes.
ELAR 180 Par RGBAW™ NA NA NA 8 NA NA NA 9 48-55 56-63 64-71 72-79 80-87 88-95 96-103 104-111 112-119 120-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 Color Macro 7 ! Internal programs: No Function Internal program 1 Internal program 2 Internal program 3 Internal program 4 Internal program 5 Internal program 6 Internal program 7 Gradient effect Shutter, strobe: LEDs off LEDs on Strobe effect slow to fast LEDs o
ELAR 180 Par RGBAW™ 128-159 160-191 192-223 224-255 ! 0-255 NA 6 8 10 ! ! ©Elation Professional, Los Angeles Ca. Pulse-effect in sequences LEDs on Random strobe effect slow to fast LEDs on General dimming/speed: Dimming (0-Black, 255- 100%) Speed from slow to fast (when running internal programs) Speed from slow to fast (when running gradient effect) 30 www.ElationLighting.
ELAR 180 Par RGBAW™ 12. WORKING WITH BUILT-IN PROGRAMS The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. The following instructions will detail the procedures for using the on-board system menu as well as using a DMX compliant controller.
ELAR 180 Par RGBAW™ lock the value into the scenes memory. You can repeat the procedure for all functions listed below: - “Auto Program” – Allows access to all of the fixture’s DMX traits.
ELAR 180 Par RGBAW™ then change to Edit Steps 01, this will be menu function 8-2-1-1. Use the “UP” and “DOWN” buttons to toggle through the scenes created in “Step 1.” Press the “ENTER” button to add a scene to the program. Tapping the “Enter” button will automatically lock the selected scene into the programs’ memory. Repeat the process until all the desired scenes have been added to the program. Each program can store a maximum of 64 scenes.
ELAR 180 Par RGBAW™ 13. LENS REPLACEMENT The ELAR 180 Par RGBAW comes with a removable front cover that allows the lens assembly to be changed out to achieve different beam angles. Lens cover is held in place by two ! turn locking fasteners. To remove the cover; 1) Turn the locking fasteners in a counter-clockwise direction. 2) Once the fasteners are loose lift the cover straight up to expose the inner lens (see illustration below). 3) Locate the 8 securing screws on the inner cover and remove them.
ELAR 180 Par RGBAW™ 14. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
ELAR 180 Par RGBAW™ 15. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
ELAR 180 Par RGBAW™ effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
ELAR 180 Par RGBAW™ 16. PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. 38 www.ElationLighting.
ELAR 180 Par RGBAW™ 17. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 39 www.ElationLighting.
ELAR 180 Par RGBAW™ 18. CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. 40 www.ElationLighting.
ELAR 180 Par RGBAW™ 19. TECHNICAL SPECIFICATIONS Power supply: 100v~240v / 50Hz~60Hz AC Power consumption: Maximum 150w LED Configuration: 60 x 3 Watt (12 x Red, 12 x Green, 12 x Blue, 12 x Amber, 12 x White) IP Rating: IP65 DMX Channels: 5, 6, 8, or 10 Channel mode DMX Drive: Standard DMX-512, 5 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
ELAR 180 Par RGBAW™ ©Elation Professional, Los Angeles Ca. 42 www.ElationLighting.
Elation Professional 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighitng.com Rev. 4/26/2010 – visage Version 1.