DLED STRIP RGBAW Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev. 01/18/2011 – visage Version 1.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 2 www.ElationLighting.
DLED STRIP RGBAW ™ TABLE OF CONTENTS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 4 2. Safety Instructions………………………………………………………........…………. 5 3. Features……………………………………………………………………………………7 4. General Guidelines………………………………………………………………………. 8 5. Fixture Overview…………………………………………………………………………. 9 6.
DLED STRIP RGBAW ™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The DLED STRIP RGBAW™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
DLED STRIP RGBAW ™ operate this fixture with the lens cover removed. Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The DLED STRIP RGBAW™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase.
DLED STRIP RGBAW ™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1.Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling.
DLED STRIP RGBAW ™ damaged, replace it immediately with a new one of similar power rating. 12.Always disconnect from main power before performing any type of service or any cleaning procedure. 13.Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 14.Please be aware that damages caused by modifications to the device are not subject to warranty.
DLED STRIP RGBAW ™ 3.
DLED STRIP RGBAW ™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. Consistent operational breaks will ensure that the fixture will function properly for many years to come. Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
DLED STRIP RGBAW ™ 5. FIXTURE OVERVIEW 1. LED Display – 4-segment menu display. Used to display the DMX address as well as all other menu functions. 2. Mode/Esc Button – This button is used to access the fixtures menu functions. 3. Up Button – The up button is used to toggle forward through the menu functions and settings. 4. Down Button – The down button is used to toggle backwards through the menu functions and settings. 5.
DLED STRIP RGBAW ™ 7. 3-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next fixture in the DMX chain via a female, 3-pin XLR jack. 8. 3-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 3pin XLR jack. 9. Fuse Holder Assembly – This assembly houses the 3.15 amp GMA safety fuse. Always replace the fuse with an exact match unless otherwise specified by an authorized Elation Service Technician.
DLED STRIP RGBAW ™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 13 www.ElationLighting.
DLED STRIP RGBAW ™ Mounting The DLED STRIP RGBAW™ is fully operational in any mounting position, hanging upsidedown, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below. ©Elation Professional, Los Angeles Ca. 14 www.
DLED STRIP RGBAW ™ Clamp Mounting The DLED STRIP RGBAW™ provides a unique mounting bracket assembly that allows the unit to stand on a flat surface or to be hung on truss via a clamp in any safe position (see the illustration above). Regardless of the mounting option you choose please be sure to refer to the safety guidelines in this manual to avoid damage to the unit and/or personal injury.
DLED STRIP RGBAW ™ 7. UNDERSTANDING DMX DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
DLED STRIP RGBAW ™ male and female XLR connector on either end of the cable. Also, remember that a DMX line must be daisy chained and cannot be split, unless using an approved DMX splitter Be sure to follow the above figure when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing.
DLED STRIP RGBAW ™ DMX-512 control connection Connect an XLR cable to the female XLR output of your controller and the other side to the male XLR input of the fixture (Please refer to the diagram below.). You can chain multiple moving heads together through serial linking. Remember to daisy-chain the “in” and “out” data connections. DMX-512 connection with DMX terminator A DMX terminator should be used in all DMX lines especially in longer runs.
DLED STRIP RGBAW ™ resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease the possibilities of erratic behavior. 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line.
DLED STRIP RGBAW ™ setting the correct DMX address on the digital display located on the back of the fixture. You can set the same starting address for all fixtures or a group of fixtures, or set different address for each individual fixture. Be advised that setting all you fixtures to the same DMX address will subsequently control all fixtures in the same fashion, in other words, changing the settings of one channel will affect all the fixtures simultaneously.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 21 www.ElationLighting.
DLED STRIP RGBAW ™ 8. DISPLAY LED INDICATOR. The DLED STRIP RGBAW ™ has a LED indicator on the display. This indicator is designed to give a quick visual indication of the fixtures’ DMX status. The illustration below details the functionality of the LED indicators. The LED indicator represents DMX signal: • If the indicators is on, a clean DMX signal is present • If the indicator is off, there is no DMX signal present ©Elation Professional, Los Angeles Ca. 22 www.ElationLighting.
DLED STRIP RGBAW ™ 9. DISPLAY MENU Default settings shaded. MODE VALU SLAV RDMX AUTO SOUN VALU FLIP D ON LOCK SET 5CH/6CH/9CH/25CH/28CH OFF/HOLD/AUTO/AUDI M-XX M-70 DMX channel Mode Status while there is no DMX Mic sensitivity Set dimmer mode(DIM1 to DIM4 DIM1/ DIM2/DIM3/DIM4 AUTO/HIGH/LOW ON/OFF ON/OFF V-1.0~V-9.
~ Edit the internal scenes DLED STRIP RGBAW ™ FADE TIME CEDT XXX X X X . (000.1S~999.9S) ON/OFF X Edit program via controller 9.1 “MODE” - Function Mode: 9.1.1 - DMX address setting – This function is used to set or adjust the fixture’s starting DMX address. Every device controlled by DMX has to have a unique starting address. The addressing feature is what allows DMX to function properly. The DMX address of a fixture is what allows it to communicate with a controller properly.
DLED STRIP RGBAW ™ see Section 10/Page 28 of this manual “Remote DMX addressing.” 9.1.2 - Internal Program Settings This function allows the internal programs to run in either stand-alone or master/salve mode. In “Master” mode the fixture will send DMX data to other fixtures connect via the DMX chain. In “Alone” mode the fixture will operate as a single fixture. The program for this mode is selected in the “Select program” section of the control menu.
DLED STRIP RGBAW ™ activated, the keys will be automatically locked in 15 seconds from the last press. In order to deactivate the keylock status, press the Mode/Esc-button for 3 seconds. 1. Access the main menu. 2. Tap the UP button until “DISP” is displayed. 3. Press ENTER, the display will show “VALU”. 4. Tap the UP button until ”LOCK” is displayed and tap the ENTER button. 5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7.
DLED STRIP RGBAW ™ Select the fan run mode This function will choose between the fan settings of Auto, High, or Low. The default setting is Auto. - Power on to preserve the MANL settings This function will preserve all the manual setting that are made in the “MANL” menu section. If this function is not activated all manual settings will be lost once the fixture is tuned off. - Restore Default This function is used to restore the factory settings of the device.
DLED STRIP RGBAW ™ access code is “038” Clear Fixture Run Time This function resets the run time to zero. .5 “Edit” Internal Program Settings: The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller.
DLED STRIP RGBAW ™ selected scene, press ENTER. You can change the channel number by tapping the UP button. 5. The display will show the DMX value for the channel that is being edited. It will be displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX value is “XX.” 6. Adjust the DMX value by tapping the UP button, until you get the expected effect for this channel. 7. Press ENTER to enter the editing of the other channels of the scene. 8.
DLED STRIP RGBAW ™ 7. Press UP, the display will read "ON". 8. Press MODE/ESC, the display shows "SC02". You successfully downloaded the first scene. 9. Adjust the Step-time as described above. 10. Call up the second scene in your controller now. 11. Repeat steps 5-11 until all desired scenes are downloaded. 12. Press MODE/ESC to exit. The number of steps can be defined under “STEP” and the scenes can be called up under “RUN.” ©Elation Professional, Los Angeles Ca. 30 www.ElationLighting.
DLED STRIP RGBAW ™ 10. DMX ADDRESSING Setting the DMX address - After the fixture is turned “ON” it will immediately complete a reset process that test all the fixture’s functions. When the reset process concludes the LED will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1.
DLED STRIP RGBAW ™ 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511. 3. Use channel 3 to set your desired DMX starting address.
DLED STRIP RGBAW ™ 11. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off. DMX CHANNEL TRAITS The charts below and on the preceding pages outline the different DMX traits for the five different DMX modes.
DLED STRIP RGBAW ™ DMX channel’s functions and their values (5-Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255 - 100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255 - 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255 - 100% Blue) Channel 4 - White: 0-255 White (0-Black, 255 - 100% White) Channel 5 - Amber: 0-255 Amber (0-Black, 255 - 100% Amber) 6-Channel mode: In this mode channel one controls all the red LEDs, channel two controls all the green LEDs, channels three controls all
DLED STRIP RGBAW ™ DMX channel’s functions and their values (6-Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255 - 100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255 - 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 255 - 100% Blue) Channel 4 - White: 0-255 White (0-Black, 255 - 100% White) Channel 5 - Amber: 0-255 Amber (0-Black, 255 - 100% Amber) Channel 6 - General dimming 0-255 Dimming (0-Black, 255- 100%) 9-Channel mode: In this mode channels 1~5 are used to control the RGBWA LE
DLED STRIP RGBAW ™ channels 6~9 will control special features. 9-Channel Mode: The charts below and on the next page detail the DMX channel layout for 9-channel assignment.
DLED STRIP RGBAW ™ 71-100 internal program 3 101-130 internal program 4 131-160 internal program 5 161-190 internal program 6 191-220 internal program 7 221-255 internal program 8 Channel 7 - Shutter, strobe No function (shutter close) 0-31 32-63 No function (shutter open) 64-95 Strobe effect slow to fast 96-127 No function (shutter open) 128-159 Pulse-effect in sequences 160-191 No function (shutter open) 192-223 Random strobe effect slow to fast 230 224-255 Store Color_mode enabl
DLED STRIP RGBAW ™ DMX channel’s functions and their values (25-Channel Mode): Channel 1 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 2 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channel 3 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 4 - White LED: 0-255 White (0-Black, 255-100% White) Channel 5 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 6 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 7 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channe
DLED STRIP RGBAW ™ 0-255 White (0-Black, 255-100% White) Channel 10 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 11 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 12 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channel 13 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 14 - White LED: 0-255 White (0-Black, 255-100% White) Channel 15 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 16 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 17 - Green LED:
DLED STRIP RGBAW ™ 0-255 Green (0-Black, 255-100% Green) Channel 23 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 24 - White LED: 0-255 White (0-Black, 255-100% White) Channel 25 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) 28-Channel mode: In this mode channels 1~25 are used to control the RGBWA LEDs and channels 26~28 will control special features. 28-Channel Mode: The charts below and on the next page detail the DMX channel layout for 28-channel assignment.
DLED STRIP RGBAW ™ Channel 5 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 6 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 7 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channel 8 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 9 - White LED: 0-255 White (0-Black, 255-100% White) Channel 10 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 11 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 12 - Green LED: 0-255 Green (0-Black, 255-100% Green) Ch
DLED STRIP RGBAW ™ Channel 18 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 19 - White LED: 0-255 White (0-Black, 255-100% White) Channel 20 - Amber LED: 0-255 Amber (0-Black, 255-100% Amber) Channel 21 - Red LED: 0-255 Red (0-Black, 255-100% Red) Channel 22 - Green LED: 0-255 Green (0-Black, 255-100% Green) Channel 23 - Blue LED: 0-255 Blue (0-Black, 255-100% Blue) Channel 24 - White LED: 0-255 White (0-Black, 255-100% White) Channel 25 - Amber LED: 0-255 Amber (0-Black, 255-100%
DLED STRIP RGBAW ™ Channel 27 - Shutter, strobe: No function (shutter close) 0-31 32-63 No function (shutter open) 64-95 Strobe effect slow to fast 96-127 No function (shutter open) 128-159 Pulse-effect in sequences 160-191 No function (shutter open) 192-223 Random strobe effect slow to fast 230 224-255 Store Color_mode enable No function (shutter open) Channel 28 - General dimming/speed: 0-255 Dimming( 0-Black , 255- 100% ) ©Elation Professional, Los Angeles Ca. 43 www.ElationLighting.
DLED STRIP RGBAW ™ 12. WORKING WITH BUILT-IN PROGRAMS The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. The following instructions will detail the procedures for using the on-board system menu as well as using a DMX compliant controller.
DLED STRIP RGBAW ™ 3. Tap the “ENTER” button to define the maximum amount of steps. Maximum amount of steps is 48. Steps will be indicated as “S-01” for a single step and “S-48” for 48 steps. Once you set the maximum amount of steps press enter to lock in the selection. Once the total amount of steps has been set advance to editing scenes. Step 2 – Building Scenes. The fixture will store a maximum of 48 scenes. These scenes are then used to create the programs.
DLED STRIP RGBAW ™ Step 3 – Playing a Program To initiate a program follow the procedure below: • the Access the main menu and use the “Up” and “Down” to toggle to “Mode” and tap “Enter” button. • In the next screen select “Run” and tap Enter. • In the next screen toggle to “Auto” and tap enter. There are now two selections, “Master” and “Alone.” Select “Master” when running multiple fixtures in a master/slave configuration.
DLED STRIP RGBAW ™ 13. User manual of RF controller BLACK OUT :The lamp will be turned off after press the button and exit to the status of Address Display. AUTO RUN:Press this button to enter the built- in program SOUND ACTIVE:Press this button to enter the sound active (Please notice that it works only if the lighting fixture has this sound active function) SPEED: After pressing PROG button, press this button and then you can adjust the speed of programme by pressing “+” or “ –“.
DLED STRIP RGBAW ™ B:Blue color adjustment button. Press this button to the full brightness of blue color and enter the status of adjustment.,.Press number+ENTER to dim the blue color. Press again, the blue color will die out. W:Press this button to the full brightness of white color and enter the status of adjustment.,.Press number+ENTER to dim the white color. Press again, the white color will die out. (Please notice that it works only if the lighting fixture has this white color function).
DLED STRIP RGBAW ™ 14. LENS REPLACEMENT The DLED STRIP RGBAW comes with a removable front cover that allows the lens assembly to be changed out to achieve different beam angles. The lens cover is held in place by ¼ turn locking fasteners. To remove the cover; 1) Turn the locking fasteners in a counter-clockwise direction. 2) Once the fasteners are loose lift the cover to expose the lens assembly (see illustration below). 3) Remove or replace the filters and reassemble.
DLED STRIP RGBAW ™ 15. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
DLED STRIP RGBAW ™ 16. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
DLED STRIP RGBAW ™ products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
DLED STRIP RGBAW ™ 17. PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. 53 www.ElationLighting.
DLED STRIP RGBAW ™ 18. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 54 www.ElationLighting.
DLED STRIP RGBAW ™ 19. CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. 55 www.ElationLighting.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 56 www.ElationLighting.
DLED STRIP RGBAW ™ 20. TECHNICAL SPECIFICATIONS Power supply: AC 100V-240V~, 50Hz/60Hz Power consumption: Maximum 100W LED Configuration: 75 x 1 Watt (15 x Red, 15 x Green, 15 x Blue, 15 x White, 15 x Amber) Weight: 27.5 Kgs / 60.6Lbs DMX Channels: 28, 25, 9, 6, or 5 (default) Channel mode DMX Drive: Standard DMX-512, 3 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 58 www.ElationLighting.
DLED STRIP RGBAW ™ ©Elation Professional, Los Angeles Ca. 59 www.ElationLighting.
Elation Professional 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighting.com Rev. 01/18/2011 – visage Version 1.