Instruction Manual R-G-B from software version 1.72/30 (Instruction version 1.26) e-mail: service@glp.de Internet: http://www.glp.
R-G-B Notes: GLP German Light Products GmbH (Instruction version 1.26) / from software version 1.
R-G-B Table of content 1 Description of Device.............................................................................................. 4 1.1 Safety Instructions ............................................................................................ 5 2 Preparation and Installation ................................................................................... 6 2.1 Mounting ........................................................................................................... 6 2.1.
R-G-B 1 Description of Device 1 1. Moving head (actively and passively cooled) 2. Arm with various cooling vents 2 3. LCD-Display/Menu (data entry) 3 4. Base with various connectors and Camlock mounting system 4 b a se sid e 1 5. Power On/Off 6. DMX- Output (3 pole) 7. DMX- Input (3 pole) 8. Micro-fuse 5x20mm, T4A 5 6 b a se sid e 2 9. Mains supply (Powercon) 10. 2x Safety eyes FUSE T4A 10 7 8 9 GLP German Light Products GmbH 10 (Instruction version 1.26) / from software version 1.
R-G-B 1.1 Safety Instructions The IMPRESSION is an advanced technology product. To guarantee smooth operation, it is necessary to follow the following instructions. The manufacturer of this device will not take responsibility of damages through any disregard of the information in this user manual. Warranty claims will also be cancelled in the event of the system casing being opened. 1. Make sure that before powering up the fixture, the fans and air inlets are clean and not blocked by anything. 2.
R-G-B Pressure in these areas could result in damages which will not be covered by the standard warranty. 10. Repair-, maintenance- and installation work should only be performed by qualified or GLP certified staff. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual. 11. Use only original spare parts. Any structural modification on the system will terminate all warranty claims. 12. Please keep this instruction manual for future reference.
R-G-B For the various mounting positions of the IMPRESSION (standing on the floor, sideways or hanging) different accessories kits are available. Using any required kits, along with the standard mounting connectors on the base of the fixture, will ensure a safe and firm installation. 1x M10 (length max.16mm) 2x Camlock quick release fasteners front side of the fixture 2.1.
R-G-B 2x Ca m lo c k 2x e ye le ts 2.1.1 Mounting in hanging position (head down) To operate the IMPRESSION in a hanging position, a half-coupler or similar clamp can be mounted directly to the bottom of the base using the M10x16 mm threaded socket. M10x16 2.1.1 Mounting in a sideway position To operate the IMPRESSION in a sideways position, please use an additional mounting bar, available from GLP or one of their agents.. This mounting bar is fixed via the two camlock quick-release connectors.
R-G-B 2x 90° Half-coupler (clamp) 1 Half-coupler (clamp) 2 without mounting bar 2.2 Securing the Device Regardless of the mounting method of the IMPRESSION you'll have to use a secondary safety wire. This safety wire can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture. Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting support.
R-G-B 2.3.2 DMX USITT DMX-512 Standard input/output in 3 pole connectors. 3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] The DMX- Addressing starts at the DMX- Address [001]. 3 The Menu Field You’ll find the control board on the side of the arm. It allows you to make all necessary adjustments of the IMPRESSION. With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys. Push the Enter-key to get to the next menu level or to confirm your settings.
R-G-B Impression Version Adjust Reads out the current CPU software version Key code xxxx Use the code for entering the calibration menu (for authorized persons only) Pan Offset Calibration for Pan-Offset Tilt Offset Calibration for Tilt-Offset Clear EEPROM Erase EEPROM memory Diagnose Diagnose functions DOWN - UP Pos Feed Pan Delta Anz Ti0Int-Err PFC Voltage Pos Feed Tilt Delta Temperature Arm Temperature Head PAN/TILT Motor Power PAN/TILT Silent Mode Internal data and function diagnose Int
R-G-B Red Instantaneous value for Red Color Wheel Instantaneous value for Color Mixing unit Tilt Instantaneous value for Tilt movement Self test Performs an automatic self-test Live time Indicates the overall operation time of the system Display Adjust the display DOWN - UP Blackout Select DMX Mode ON/OFF: Display OFF Please select the desired DMX Mode Compressed Fixture works in "Compressed" mode see also sectiion 4 Normal Fixture works in "Normal" mode see also section 4 HighRes
R-G-B 4 DMX Channel Selection (DMX Protocol) Normal-Mode 14 DMX channels Channel Function Time and Value 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Color (fixed) 0 .. 660° High- Pos ... High- Pos + 2,6° (16 Bit) 0 ..
R-G-B Channel Function Time and Value RESET (Normal Mode) 13) MoveNo movement ment Movement Size Phase PAN 1 0° 1 90° 1 180° 1 270° PAN 2 0° 2 90° 2 180° 2 270° PAN 3 0° 3 90° 3 180° 3 270° PAN 4 0° 4 90° 4 180° 4 270° TILT size / phase see also PAN PAN / TILT size / phase see also PAN PAN / TILT (inverse) size / phase see also PAN Circle size / phase see also PAN Circle (inverse) size / phase see also PAN Lying eight size / phase see also PAN Random movement size see also PAN 14) Speed Pan/Tilt relative
R-G-B Compress-Mode 10 DMX channels Channel Function Time and Value 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Color (fixed) 0 .. 660° High- Pos ... High- Pos + 2,6° (16 Bit) 0 ..
R-G-B High Resolution (Extended) -Mode 13 DMX Channels Channel Function Time and Value DMX HEX % 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Redcoarse 6) Red-fine 7) Greencoarse 8) Greenfine 9) Bluecoarse 10) Blue-fine 11) Shutter 0 .. 660° 2-4s 0..255 00..FF 0..100 High- Pos ... High- Pos + 2,6° (16 Bit) 0 .. 300° 1-2s 0..255 0..255 00. .FF 00..FF 0..100 0..100 High- Pos … High- Pos + 1,2° (16 Bit) Color mixing system – Red 0 - 100% 0..255 0..255 00..F F 00..FF 0..100 0..
R-G-B Locking and unlocking the Control Panel You can lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the same time. Additional shortcut features when switching on the fixture a) 1200Hz Mode (Hold down the UP- button during power ON) After switching on, the fixture the LEDs will be operated with a Pulse Width Modulation (PWM) of 1200Hz. In addition, all standard settings will be loaded (DMX start address [001], Normal Mode).
R-G-B 5 Maintaining and Cleaning the IMPRESSION The IMPRESSION is a low maintenance fixture. It is only necessary to clean the air inlets and outlets as well as the optical LED lenses from time to time. For safe operation it is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on, or within, the fixture. If they do, the fixture's light output will be significantly reduced, and damages to the fixture may occur.
R-G-B 6 Technical Specifications Power supply Power consumption 350 VA (Watt) Power Input ~100-240 V AC, 50-60 Hz (auto sensing input) Fuse protection Micro-fuse 5x20 mm, T 4A Operational Parameters Max. Ambient 45°C / 113°F (integrated overheating switch) Temperature Mounting Position Any (see chapter mounting) Lighting System - Additive Color mixing LED Type 90x Luxeon K2 High-power- LEDs Lifetime 50.
R-G-B 7 Index B BGV C1............................................................ 6 C Circumference ...............................................18 Cleaning.........................................................18 Compress-Mode ....................................15, 16 Mounting in hanging Position .......................... 8 Mounting in sidewise Position ......................... 8 Mounting on the Floor ..................................... 7 N Normal-Mode .........................................
R-G-B GLP German Light Products GmbH (Instruction version 1.26) / from software version 1.