E L A TI ON | PLATINUM BEAM 5R EXTREME™ | user manual 1.0 PLATINUM BEAM 5R EXTREME™ user manual 1.
www.elationlighting.com ©2014 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
www.elationlighting.
www.elationlighting.com GENERAL INFORMATION INTRODUCTION Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The PLATINUM BEAM 5R EXTREME™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
www.elationlighting.com CUSTOMER SUPPORT Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional®. ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST Voice: 323-582-3322 Fax: 323-832-9142 E-mail: support@elationlighting.
www.elationlighting.com 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
www.elationlighting.com SAFETY INSTRUCTIONS The PLATINUM BEAM 5R EXTREME™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. This device falls under PROTECTION CLASS 1. It’s essential this device be grounded properly.
www.elationlighting.com GENERAL GUIDELINES • N E V E R O P E N T H I S F I X T U R E W H I L E I N U S E ! • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
www.elationlighting.com DISCHARGE LAMP WARNING This fixture is fitted with a DISCHARGE LAMP, which is highly susceptible to damage if improperly handled. NEVER touch the lamp with your bare hands, as the oil from your hands will shorten the life of the lamp. Also, NEVER move the fixture until the lamp has had ample time to cool. Lamps are NOT covered under warranty conditions. Avoid switching the fixture ON and OFF repeatedly in short intervals, as this will reduce lamp life and intensity.
www.elationlighting.com FIXTURE OVERVIEW 10 1. LED Assembly 2. LCD Menu Function Display 3. Wireless DMX Indicator 4. DC Switch 5. Microphone 6. LEFT Button 7. DOWN Button 8. RIGHT Button 9. MODE/ESC Button 10. UP Button 11. ENTER Button 12. Wireless DMX Antenna 13. Carrying Handle(s) 14. Lamp Access/Cover Panel 15. 3pin DMX Input 16. 3pin DMX Output 17. 5pin DMX Output 18. 5pin DMX Input 19. powerCON Input 20. Fuse PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com LAMP INSTALLATION INSTRUCTIONS L A M P R E P L A C E M E N T Please note that due to the nature of the Phillips™ Platinum 5R Lamp and the optical path of the Elation PLATINUM BEAM 5R EXTREME fixture, the lamp MUST BE replaced at 2,000 hours. Use only Genuine Original Phillips™ Platinum 5R Lamps. Other brand lamps may cause damage and void warranty! INSTALLING OR REPLACING THE LAMP To ensure a proper/safe lamp change, carefully read all the following instructions.
www.elationlighting.com LAMP SAFETY INSTRUCTIONS • ALWAYS replace lamp every 2,000 Hours. • Use only Genuine Original Phillips™ Platinum 5R lamps. Other brand lamps may cause damage and void the warranty! • NEVER touch the lamp with your bare hands, as the oil from your hands will shorten the life of the lamp. • Always disconnect the fixture’s main power supply before replacing lamp. • Allow fixture to cool for at least 15 minutes before attempting any type of service.
www.elationlighting.com 2. Gently remove (2) Red Wires connected to spade terminals on base of lamp. 3. Using two fingers on your RIGHT hand, pull the retention handle OUT and towards the RIGHT as far as possible. 13 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 4. While pulling the retention handle with your RIGHT hand, use your LEFT hand to gently twist the lamp COUNTERCLOCKWISE to remove it from under the retention brackets. 14 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 5. Using two fingers on your RIGHT hand, pull the retention handle OUT and towards the RIGHT as far as possible. 6. While pulling the retention handle with your RIGHT hand, use your LEFT had to gently install the lamp under the retention brackets by holding the lamp at a slight angle and positioning it until it is flush with the base. 15 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 7. While still holding the retention handle with your RIGHT hand, gently turn the lamp CLOCKWISE with your LEFT hand until the lamp is correctly aligned under the retention brackets. 8. Release the retention handle with your RIGHT hand and make sure the handle is upright and not at an angle. 16 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 9. Gently attached (2) Red Wires connected to spade terminals on base of lamp. 10. Replace the lamp cover back into place by securing (4) screws marked “A”, “B”, “C”, and “D”. 11. Be sure to reset the LAMP HOURS in the system menu to prevent the protection circuitry from accidently shutting off the lamp during normal operation. 12.
www.elationlighting.com LAMP HOURS RESET PROCEDURE 1. Activate the main menu by pressing MODE/ESC and toggle to “Information”. 2. Press ENTER and press UP or DOWN to toggle to “Time Information”. 3. Press UP or DOWN to toggle to “L-Timer Password” and press ENTER. Then press UP or DOWN to enter the reset pass code, “038” and press ENTER to confirm. The display will automatically revert to “L-Timer Password”, next press UP or DOWN to toggle down to “Clear Lamp Time”. 4. Press ENTER and select “ON”.
www.elationlighting.com FIXTURE INSTALLATION T he el ec tri c c onnec ti on m ust onl y b e c arri ed out b y a qu al if i ed el ec tri c i an. CAUTIONS • For added protection, mount the fixture in areas outside walking paths, seating areas, or in areas were unauthorized personnel might reach the fixture. • Ambient operating temperature range for this fixture is 14° to 113°F. (-10° to 45°C) Do not use the fixture under or above this temperature.
www.elationlighting.com MOUNTING POINTS • Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. • Fixture is fully operational in the specific mounting positions as illustrated below.
www.elationlighting.com CLAMP MOUNTING The PLATINUM BEAM 5R EXTREME™ provides a unique mounting bracket assembly that integrates the bottom of the base, the included Omega Brackets (x2) and safety cable rigging point in one unit (see the illustration below). When mounting this fixture to truss be sure to secure an appropriately rated clamps to the included omega brackets using a M10 screw fitted through the center hole of the Omega Bracket.
www.elationlighting.com UNDERSTANDING DMX DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
www.elationlighting.com Be sure to follow the above figure when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing. Grounding the shield could cause a short circuit and erratic behavior.
www.elationlighting.com DMX-512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs. The use of a terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line.
www.elationlighting.com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture.
www.elationlighting.com FIXTURE MENU ON-BOARD SYSTEM MENU The PLATINUM BEAM 5R EXTREME™ comes with an easy to navigate system menu. The next section will detail the functions of each command in the system menu. LCD MENU CONTROL PANEL The control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the PLATINUM BEAM 5R EXTREME™. During normal operation, pressing MODE/ESC button once will access the fixture’s main menu.
www.elationlighting.com 27 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com FUNCTION - Set DMX Address Define desired DMX address via the Control Panel. FUNCTION - DMX Value Display DMX 512 value of each channel. FUNCTION - Set To Slave Define fixture slave mode (Slave1, Slave2, Slave3). FUNCTION - Auto Program Define fixture mode (Master or Alone) for running Auto Programs. Select desired internal programs under “Select Program”, set the number of steps under “Edit Program”, and edit individual scenes under “Edit Scenes”.
www.elationlighting.com INFORMATION - Time Information - Last Run Hours Displays fixture run time for a given period of time (i.e. rental period). This counter can be reset. INFORMATION - Time Information - Lamp Hours Displays lamp total run time. This counter should be reset at each lamp change. INFORMATION - Time Information - Lamp Off Time Displays lamp run time from the last power ON. This counter is automatically reset after each time the lamp is powered ON.
www.elationlighting.com LAMP CONTROL - Lamp ON at Temp The fixture is designed to shut the lamp OFF when an excessive temperature is sensed inside the head by the on-board CPU. The lamp is shut OFF to prevent damage to the lamp and avoid possible internal damage to the fixture head. This function sets the MIN internal operating temperature of the fixture head before the lamp will restrike after the lamp has been automatically shut OFF.
www.elationlighting.com PERSONALITY - Status Settings – Hibernation Select desired Hibernation time. PERSONALITY – Fans Control Select desired Fan setting. PERSONALITY - Display Setting – Shutoff Time Define how many minutes before the LCD Menu display will automatically shut OFF. PERSONALITY - Display Setting – Display Reverse When ON, the LCD Menu display by is rotated (inverted) 180°.
www.elationlighting.com RESET FUNCTION - Reset Others Reset ALL other motors not associated previously listed commands to Home Position. EFFECT ADJUST – Test Channel Select and auto test each individual channel function independently from the DMX control board. EFFECT ADJUST – Manual Control Select and manually test and fine adjust each individual channel function Independently from DMX control board. This function will center PAN and TILT motors and set dimmer to 100%.
www.elationlighting.com EDIT PROGRAM – Edit Scenes Edit any of the scenes of the internal Auto Programs. EDIT PROGRAM – Record Controller The fixture features an integrated DMX-recorder by which you can transmit the programmed scenes from your DMX-controller to the moving head. Adjust the desired scene numbers via the encoder (from – to). When you call up the scenes at your controller, they will automatically be transmitted to the moving head.
www.elationlighting.com EDIT PROGRAM – Record Controller – Working With Built-In Program [continued] 2. Automatic Program Run • Select “Function Mode”. • Press ENTER to confirm. • Select “Auto Program”. • Press ENTER to confirm. • Select “Master” or “Alone”. • Press ENTER to confirm. • Press MODE/ESC in order to return to the main menu. 3. Program Selection for Auto Pro Part • Select “Edit Program”. • Press ENTER to confirm. • Select “Select Programs”. • Press ENTER to confirm.
www.elationlighting.com EDIT PROGRAM – Record Controller – Working With Built-In Program [continued] 5. Automatic Scene Recording • Select “Edit Program”. • Press ENTER to confirm. • Select “Edit Scenes”. • Select desired scene numbers. A maximum of 250 scenes can be programmed. • Press ENTER to confirm. • Press MODE/ESC in order to return to the main menu.
www.elationlighting.com INTERNAL WIRELESS DMX RECIEVER (EWDMX) The PLATINUM BEAM 5R EXTREME™ is equipped with an internal Elation Wireless DMX Receiver, which is fully compatible with an Elation Wireless DMX System. WORKING WITH THE INTERNAL WIRELESS DMX (EWDMX) System Access the “Wireless DMX” sub menu from the “PERSONALITY” menu. The “Wireless DMX” sub menu allows you to “Activate” (turn ON) the system, “Deactivate” (turn OFF) the system, or “Reset” (CLEAR) the EWDMX system.
www.elationlighting.com CLEARING EWDMX TRANSMITTER LINK • Access the fixture’s main menu and toggle to the “PERSONALITY” menu, then access the “Wireless DMX” sub menu and select “Clean WDMX Memo” to clear any existing link between the fixture and a EWDMX Transmitter. The EWDMX indictor on the fixture will turn solid RED when the link is severed. • You may also clear the link directly from the EWDMX Transmitter.
www.elationlighting.com DMX CHANNEL FUNCTIONS AND VALUES 38 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 39 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com 40 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com ERROR CODES When power is applied, the unit will automatically enter a “Reset/Test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “0Er” it means there is some type of error with the Pan motor.
www.elationlighting.com Color Wheel Er The color wheel is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or defective motor IC drive on main PCB). Gobo Wheel 1 Er The gobo-wheel is not located in the default position after start-up or after a reset command.
www.elationlighting.com CLEANING AND MAINTENANCE CLEANING Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. • Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation.
www.elationlighting.com TECHNICAL SPECIFICATIONS FEATURES 3° Sharp Pin Spot Beam CTO and CTB Color Correction 8 Facet Rotating Prism and Frost Effects Super Fast 16 bit 3-Phase Pan and Tilt Motors Flicker Free Operation for TV and FILM Internal EWDMX Wireless DMX Receiver Remote Device Management Protocol Support SOURCE 189W Platinum 5R Lamp 2,000 Hour Average Life PHOTOMETRIC DATA 100,100 LUX 9,299 FC @49.
www.elationlighting.com COLORS + GOBOS PHOTOMETRIC DATA Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. 45 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com DIMENSIONAL DRAWINGS CIRCUIT SCHEMATICS Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. 46 PLATINUM BEAM 5R EXTREME™ User Manual 1.
www.elationlighting.com OPTIONAL ACCESSORIES ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCPLAT Dual Flight Case For Platinum Beam 5R EXTREME™ DRCPLATQUAD Quad Flight Case For Platinum Beam 5R EXTREME™ ELO211 Eloader II™ Software Updater Box EWDMXSYSTEM Wireless DMX System (1 Transmitter, 1 Receiver) EWDMXT Wireless DMX Transmitter EWDMXR Wireless DMX Receiver AC3PDMX5PRO 5 ft. (1.5m) 3pin PRO DMX Cable AC3PDMX10PRO 10 ft.