user manual E L A TI ON | PLATINUM SPOT LED PRO II™ | user manual PLATINUM SPOT LED PRO II™
www.elationlighting.com ©2014 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
www.elationlighting.
www.elationlighting.com GENERAL INFORMATION INTRODUCTION Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The PLATINUM SPOT LED PRO II™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
www.elationlighting.com CUSTOMER SUPPORT Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional®. ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST Voice: 323-582-3322 Fax: 323-832-9142 E-mail: support@elationlighting.
www.elationlighting.com 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
www.elationlighting.com SAFETY INSTRUCTIONS The PLATINUM SPOT LED PRO II™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. This device falls under PROTECTION CLASS 1. It’s essential this device be grounded properly.
www.elationlighting.com GENERAL GUIDELINES • N E V E R O P E N T H I S F I X T U R E W H I L E I N U S E ! • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
www.elationlighting.com FIXTURE OVERVIEW 1: Lens 2: Display 3.
www.elationlighting.com FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decorations, pyrotechnics, etc. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. CAUTIONS • For added protection, mount the fixture in areas outside walking paths, seating areas, or in areas were unauthorized personnel might reach the fixture.
www.elationlighting.com MOUNTING POINTS • Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. • Fixture is fully operational in the specific mounting positions as illustrated below.
www.elationlighting.com CLAMP MOUNTING The PLATINUM SPOT LED PRO II™ provides a unique mounting bracket assembly that integrates the bottom of the base, the included Omega Brackets (x2) and safety cable rigging point in one unit (see the illustration below). When mounting this fixture to truss be sure to secure an appropriately rated clamps to the included omega brackets using a M10 screw fitted through the center hole of the Omega Bracket.
www.elationlighting.com UNDERSTANDING DMX DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant.
www.elationlighting.com Be sure to follow the above figure when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing. Grounding the shield could cause a short circuit and erratic behavior.
www.elationlighting.com DMX-512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs. The use of a terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line.
www.elationlighting.com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture.
www.elationlighting.com FIXTURE MENU ON-BOARD SYSTEM MENU The PLATINUM SPOT LED PRO II™ comes with an easy to navigate system menu. The next section will detail the functions of each command in the system menu. LCD MENU CONTROL PANEL The control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the PLATINUM SPOT LED PRO II™. During normal operation, pressing MODE/ESC button once will access the fixture’s main menu.
www.elationlighting.com Information Function Default settings shaded. Set DMX Address DMX Value Slave Mode Auto Program Sound Control Time Information Temperature Info Personality Software Version A001~AXXX PAN…… Slave1, Slave2, Slave3 Master / Alone Master / Alone Current Time Total Run Time Last Run Time LastRun Password Clean Last Run Head Temperature V1.
Edit Program Users Mode Set Effect Adjust Reset Function www.elationlighting.
www.elationlighting.com FUNCTION - Auto Program Define fixture mode (Master or Alone) for running Auto Programs. Select desired internal programs under “Select Program”, set the number of steps under “Edit Program”, and edit individual scenes under “Edit Scenes”. FUNCTION – Sound Control Define fixture mode (Master or Alone) for running Auto Programs via sound activation, default is Master. INFORMATION - Time Information - Current Time Displays fixture run time from last power ON.
www.elationlighting.com PERSONALITY - Status Settings - Address Via DMX When ON, define the desired DMX address via an external controller. 1. Connect the fixture to the external controller and power ON. 2. Set the DMX value of Channel 1 on the controller to (7). 3. Set the DMX value of Channel 2 on the controller to (7) or (8). When set to (7), the DMX address can be set between (1) and (255). When set to (8), the DMX address can be set between (256) and (511). 4.
www.elationlighting.com PERSONALITY - Status Settings – Mic Sensitivity Select desired sensitivity of internal microphone for sound control. PERSONALITY - Status Settings – Hibernation Select desired Hibernation time. PERSONALITY – Service Setting - Password Display the fixture timer password. (050) PERSONALITY – Service Setting - RDM PID Select various submenus via RDM. RDM stands for "Remote Device Management", which provides the ability to control the device remotely while connected to a DMX-bus.
www.elationlighting.com PERSONALITY – Reset Default When ON, all factory settings are restored. RESET FUNCTION - Reset ALL Reset ALL internal motors to Home Position. RESET FUNCTION - Reset Pan & Tilt Reset only Pan & Tilt motors to Home Positions. RESET FUNCTION - Reset Colors Reset only Color Wheel to Home Position. RESET FUNCTION - Reset Gobos Reset only Gobo Wheels to Home Positions. RESET FUNCTION - Reset Others Reset ALL other motors not associated previously listed commands to Home Position.
www.elationlighting.com USER MODE SET – User Mode Select operating mode, which includes DMX Channel and User defined modes. USER MODE SET – Edit User Mode Create user defined channel orders allowing the fixture to match the channel order of other fixtures on the market for easier operation. A total of three user modes may be configured: User Mode A, User Mode B, and User Mode C. EDIT PROGRAM – Select Programs Select one of the (10) user defined internal Auto Programs.
www.elationlighting.com EDIT PROGRAM – Record Controller – Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can start 3 different Slave units, which run 3 different programs. The Master unit sends the 3 program parts in a continuous loop. The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to. If e.g.
www.elationlighting.com EDIT PROGRAM – Record Controller – Working With Built In Programs [continued] 3. Program Selection for Auto Pro Part • Select “Edit Program”. • Press ENTER to confirm. • Select “Select Programs”. • Press ENTER to confirm. • Select “Auto Pro Part 1”, “Auto Pro Part 2” or “Auto Pro Part 3”, and select which Slave program is to be sent. Selection “Part 1” means, that the Slave unit runs the same program as the master units. • Press ENTER to confirm.
www.elationlighting.
www.elationlighting.com INTERNAL WIRELESS DMX RECIEVER (EWDMX) The PLATINUM SPOT LED PRO II™ is equipped with an internal Elation Wireless DMX Receiver, which is fully compatible with an Elation Wireless DMX System. WORKING WITH THE INTERNAL WIRELESS DMX (EWDMX) System Access the “Wireless DMX” sub menu from the “PERSONALITY” menu. The “Wireless DMX” sub menu allows you to “Activate” (turn ON) the system, “Deactivate” (turn OFF) the system, or “Reset” (CLEAR) the EWDMX system.
www.elationlighting.com CLEARING EWDMX TRANSMITTER LINK • Access the fixture’s main menu and toggle to the “PERSONALITY” menu, then access the “Wireless DMX” sub menu and select “Clean WDMX Memo” to clear any existing link between the fixture and a EWDMX Transmitter. The EWDMX indictor on the fixture will turn solid RED when the link is severed. • You may also clear the link directly from the EWDMX Transmitter.
www.elationlighting.com DMX CHANNEL FUNCTIONS AND VALUES ELATION© PLATINUM SPOT LED PRO II™ SKU# EPS060 - DMX Channel Values / Functions (22 DMX Channels) Specifications are subject to change without any prior written notice.
www.elationlighting.com ELATION© PLATINUM SPOT LED PRO II™ SKU# EPS060 - DMX Channel Values / Functions (22 DMX Channels) Specifications are subject to change without any prior written notice.
www.elationlighting.com ELATION© PLATINUM SPOT LED PRO II™ SKU# EPS060 - DMX Channel Values / Functions (22 DMX Channels) Specifications are subject to change without any prior written notice.
www.elationlighting.com ERROR CODES When power is applied, the unit will automatically enter a “Reset/Test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “0Er” it means there is some type of error with the Pan motor.
www.elationlighting.com ELATION© PLATINUM SPOT LED PRO II™ ERROR CODES Specifications and features are subject to change without any prior written notice. ERROR CODE DESCRIPTION PAN Er The PAN movement is not located in the default position after the reset. This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the main PCB).
www.elationlighting.com ELATION© PLATINUM SPOT LED PRO II™ ERROR CODES Specifications and features are subject to change without any prior written notice. ERROR CODE DESCRIPTION Zoom Er The Zoom movement is not located in the default position after the reset. This message will appear after the reset of the fixture reset if the magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or defective motor IC drive on main PCB).
www.elationlighting.com CLEANING AND MAINTENANCE C A U T I O N Disconnect power before cleaning or maintenance. CLEANING Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics.
www.elationlighting.
www.elationlighting.
www.elationlighting.
www.elationlighting.com DIMENSIONAL DRAWINGS Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
www.elationlighting.
www.elationlighting.com OPTIONAL ACCESSORIES ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCPLAT Dual Road Case For Platinum Spot LED PRO II™ DRCPLATQUAD Quad Road Case For Platinum Spot LED PRO II™ ELO211 Eloader II™ Software Updater Box EWDMXSYSTEM Wireless DMX System (1 Transmitter, 1 Receiver) EWDMXT Wireless DMX Transmitter EWDMXR Wireless DMX Receiver AC3PDMX5PRO 5 ft. (1.5m) 3pin PRO DMX Cable AC3PDMX10PRO 10 ft.