THE PIPE DOES NOT CROSS THE REAR PANEL OF THE COOKER.
IN CASE OF CROSSING THE BACK PANEL, ENSURE THE PIPE IS POSITIONED
CLOSE TO THE BOTTOM PART OF THE APPLIANCE.
Fig. 7.1
POSSIBLE GAS CONNECTIONS
GAS CONNECTION WITH A RUBBER HOSE
Important!
A rubber hose connection shall only be made if permitted by the applicable local
regulations.
The gas connection is made up of:
the terminal tting of the inlet pipe;
the brass connector;
sealing washer/s;
the appropriate hose holder (for Natural/Town gas or LPG).
Important!
Ifthebrassconnectorisnotalreadyttedontheappliance(butsuppliedinasepa-
rate kit), screw that connector to the terminal of the gas inlet pipe before starting the
connection to the gas supply.
Use two spanners when connecting the brass connector.
Connecting the cooker to Natural or Town gas
1. If not already tted, t the Natural/Town gas hose holder on the inlet pipe, making sure
that you place the sealing washer between them (as shown in Fig. 7.2).
2. Connect the cooker to the gas supply using a suitable rubber hose (internal diameter
13 mm).
The hose must comply with the applicable local regulations and be of the correct con-
struction for the type of gas being used.