the exiple pipe does not exceed 2000 mm in length (or refer to applicable local regula-
tions) and does not come into contact with sharp edges, corners or moving parts. Use
a single exible pipe only; never connect the cooker with more than one exible pipe.
the exible pipe can easily be inspected along its entire length to check its condition; if it
has an expiry date, it should be replaced before that date.
if using a exible pipe which is not entirely made of metal, make sure that it does not
come into contact with any part of the cooker with a surface temperature of 70°C or
above (or refer to applicable local regulations).
the hose is not subject to excessive heat by direct exposure to ue products or by con-
tact with hot surfaces.
the rigid or exible pipe is replaced if it shows signs of wear or damage.
a gas pressure regulator, in compliance with the applicable local regulations, is installed
when connecting to an LPG cylinder.
you inform the customer that the cylinder valve or the supply valve immediately by the
appliance should be closed when the cooker is not in use.
you inform the customer that the rigid or exible pipe should not be subjected to corro-
sion by acidic cleaning agents.
After connecting the cooker to the gas supply, make sure that you
check that the connections are correctly sealed using a soapy solution, but never a
naked ame.
check whether the injectors are correct for the type of gas being used. If not, follow the
instructions under “GAS MAINTENANCE”.
replace the sealing washer/s on the slightest sign of deformation or imperfection. The
sealing washer/s is/are the part/s which guarantee/s a good seal in the gas connection.
use two spanners when connecting the rigid or exible pipe (Fig. 7.3).
Gasconnectionwithrigidorexiblepipe
Note: if already tted on the inlet pipe,
remove the rubber hose holder
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
(#) If not already tted on the inlet
pipe, it is supplied with the
appliance in a separate kit
Inlet pipe
Manifold male
pipe tting
Sealing washer (#)
Sealing washer (#)
Brass connector (#)
Flexible pipe
(not supplied)
Rigid pipe
(not supplied)
Fig. 7.3