GAS MAINTENANCE
LUBRICATION OF THE GAS TAPS
In case of difculty in the gas taps operation, call Service.
IMPORTANT
Allinterventionregardinginstallationmaintenanceoftheappliancemustbefullledwith
original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Town Gas
G110 8 mbar
Ø injector
[1/100 mm]
Ring
opening
[mm]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Auxiliary (A) 1,00 0,40 50 - 77 - 145 -
Semi-rapid (SR) 1,75 0,45 66 - 101 - 192 -
Rapid (R) 3,00 0,75 87 - 129 - 280 -
Oven 3,20 0,85 86 Fully open(*) 130 5 (*) 270 5 (*)
(*) = Reference value
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Oven 6,40