Product data

23
J
Fig. 7.5
Fig. 7.4
REPLACEMENT OF THE INJECTORS
If the injectors are not supplied they can
be obtained from the “Service Centre”.
Select the injectors to be replaced accor-
ding to the “Table for the choice of the
injectors”.
The nozzle diameters, expressed in hun-
dredths of a millimetre, are marked on the
body of each injector.
REPLACEMENT OF THE INJEC-
TORS OF THE COOKTOP BUR-
NERS
To replace the injectors proceed as follows:
Remove pan supports and burners
from the cooktop.
Using a wrench, substitute the nozzle
injectors “J(g. 7.4) with those most
suitable for the kind of gas for which it
is to be used.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
ADJUSTING OF THE MINIMUM OF
THE COOKTOP BURNERS
In the minimum position the ame must
have a length of about 4 mm and must re-
main lit even with a quick turn from the ma-
ximum position to that of minimum.
The ame adjustment is done in the fol-
lowing way:
Turn on the burner.
Turn the tap to the MINIMUM position.
Take off the knob.
With a small at screwdriver turn the
screw inside the tap rod to the correct
regulation (g. 7.5).
Normally for G30/G31 (LPG), tighten up
the regulation screw.