PORTABLE AIR-CONDITIONER MODEL: EWS-9001C Owner’s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the set. See the label attached on the set and quote this information to your dealer when you require service.
REMOVE ALL PACKING MATERIALS FROM THIS PRODUCT BEFORE USING IT. THIS APPLIANCE MUST BE INSTALLED ON A FLAT SURFACE. PLEASE ENSURE THE ELECTRICITY SUPPLY TO THIS APPLIANCE IS DISCONNECTED BEFORE INSTALLING. Please read this instruction carefully. It is advisable to keep this instruction manual in a safe place for future reference. SAFETY PRECAUTIONS 1. Keep this appliance out of reach from children. Do not let them to operate the appliance without supervision. 2.
PRODUCT DESCRIPTION 1. Control Panel 2. Horizontal Louver 3. Vertical Louver 4. Handle 5. Air-inlet Grille 6. Castors 7. Exhaust Pipe 8. Water Filling Port 9. Power Cord Hook 10. Air Filter 11. Air Outlet Grille 12. Connector of Drainage 13. Inner Tank Water Level Indicator 14.
INSTALLATION Place it on a flat and even place, and keep it at least 50cm away from its surrounding object. Fix the square end of the exhaust duct to the air outlet behind the panel. Insert the exhaust duct assembly into the window sealing plate; adjust opening width of window so that the window can match with the sealing plate properly. The length of the sealing plate is adjustable.
MOUNTING IN THE WALL CORRECT BENDING INCORRECT INSTALLATION It’s important to keep the exhaust duct smooth. Incorrect installation will affect the efficiency of the appliance. Prevent the exhaust duct from seriously bending. Ensure air can flow smoothly in the duct. WARNING: The exhaust duct is designed especially for this model. Don’t replace or lengthen it; otherwise, it will result in operating failure. NOTICE: Maximum length of the exhaust duct is 1,500mm.
OPERATION PROCEDURE AND MODULATON 1. ON/OFF Press the key to turn ON/OFF the appliance. 2. MODE Press this key to select cool, dry or fan mode. 3. UP/DOWN Press this key to set temperature or adjust the time in Timer Mode. Press both button simultaneously to switch between Celsius and Fahrenheit. 4. SWING Press this key to make the vertical louver swing automatically. Press once again to stop the swing. 5. SPEED Press the key to select High, Medium or Low fan speed. 6.
LCD DISPLAY : Cool Mode Indicator : Dry Mode Indicator : Fan Speed Indicator : Water Full Indicator : In Cooling Mode it displays the set temperature. In Dehumidifying or Fan mode, it displays room temperature. When it shows E2 : The room temperature sensor is faulty. When it shows E3 : The evaporator sensor is faulty. When it shows df : The appliance is defrosting automatically. : Water Filling Indicator : Timer indicator to turn on or turn off the appliance.
REMOTE CONTROL Power : To turn ON/OFF the unit. Timer : To set the ON/OFF timer. Swing : To swing/stop the louver. ºC ºF : To display Celsius (ºC) or Fahrenheit (ºF). Cooling : To select Cooling Mode. Dry : To select Dry Mode. Fan : To select Fan Only Mode. Up : To set temperature up / Timer. Down : To set temperature down / Timer. High : To set fan speed to High. Medium : To set fan speed to Medium. Low : To set fan speed to Low. Economy : To set energy saving mode (only in cool).
OPERATING METHOD Cooling mode When the cooling mode is selected after power ON, the cooling mode indicator lights up. Press Up/Down key to adjust setting temperature (18ºC to 30ºC). Press Speed key to choose High, Medium or Low fan speed. Fan mode When the fan mode is selected, the wind mode indicator lights up. Press Speed key to choose High, Medium or Low fan speed. In this mode the temperature cannot be set. Note: The air outlet duct is not necessary in this mode.
WATER FILLING METHOD The condensing water from the appliance is recycled to improve efficiency through cooling condenser. At the same time it could lower the noise and save energy. When the condensing water is not enough for pumping, the water filling indicator will illuminate. You may add water to the water tank as shown below. Note: Filling water into the water tank helps to reduce the heat of the compressor. It is advisable to maintain the water level to protect the compressor from overheating.
CLEANING AND MAINTENANCE Notice: In order to avoid electric shock, please turn off the appliance and unplug before maintenance or repair. EXTERNAL CLEANING Always switch off and unplug before cleaning. Clean the appliance with a damp cloth with mild cleaner. Do not use chemical, steel, wooden or abrasive cleaners to clean the appliance. After cleaning, wipe the appliance until it is completely dry. Prevent water from spattering in the appliance during cleaning.
SEASONAL CLEANING If the appliance will not be used for a long time: Pull out the rubber plug to drain off the remaining water. Operate the appliance in wind mode for 2 hours until the inside is dry. Turn off the appliance and unplug from electrical mains. Wash the filter screen and reassemble it. Dismantle the exhaust duct and keep it properly. Cover the appliance with a plastic bag and store it at a dry place. Remove the batteries from the remote control and keep it with the appliance.
MAIN SPECIFICATION Model No : EWS-9001C Cooling Capacity : 9,000 BTU/h Thermostat Range : 18ºC to 30ºC Max Air Flow : 425m3/h Rated Voltage : 220-240V Rated Frequency : 50Hz Power Consumption : 1050W Refrigerant : R410a / 420g NOTICE This product must not be disposed together with domestic waste. It has to be disposed at an authorized place for recycling of electrical and electronic appliances.