Specification Sheet

2042 E. Vernon Ave., Vernon, CA 90058 • Tel (323) 231-2600 Fax (323) 231-3200 • elcolighting.com
© ELCO Lighting 2018. All rights reserved • Rev. 28 Jun 2018 • ELCO Lighting reserves the right to make specification and design changes without notice.
Page 1 of 1
Project name:
Fixture type:
Date:
5" Double Wall Airtight IC
Housing
Features
5” Airtight IC Double wall aluminum housing for direct
contact with ceiling insulation.
Integral thermal protector guards against improper
lamping.
Lamp: PAR
UL Listed for damp location and for feed through.
Specifications
Wattage 100W
Voltage 120V
Lamp Type Medium Base (E26)
Damp LocationListed
Technical Details
Construction: 󰾬󰾬
IC rated for direct contact with insulation, for use in IC or non-IC conditions.
• Housing adjusts in frame to accommodate up to 1 1/4" ceiling thickness.
• Airtight housing with gasket to restrict airflow in accordance with ASTM E-283 air-tight requirements.
• Aluminum housing for greater heat dissipation. Stamped galvanized steel frame.
Installation: Designed for ceiling plenums where 2x8 joists or taller are used. High strength hanger bars can
easily be nailed to joists. Maximum hole cutout is 5 1/2". Suitable for T-grid and drop ceiling applications. See
installation sheet for detailed information.
Junction Box: Positioned to accommodate straight conduit runs. Seven 1/2" trade size pryout conduit
knockouts, 4 Romex pryouts with strain relief.
Hanger Bars: Pre-installed hanger bars with True Nail facilitate easy installation in regular lumber,
engineered lumber, and laminated beams. Integral T-bar slots for easy installation in T-grids. Spans up to 24"
and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange
allows for single-person installation while aligning the housing with the joists.
Electrical:
• Input Voltage: 120V AC.
• Thermally protected against improper lamping.
Trims: Compatible with ELCO 5" Line Voltage PAR trims.
Lamp: Designed for use with Medium Base (E26) PAR lamps up to 100W.
Listings:
• UL Listed for Damp Location.
• UL Listed for Feed Through.
UL Listed for Direct Contact with Insulation and Combustible Material.
• Airtight per ASTM E-283.
• Install a JA8-2016-E lamp/luminaire for Title 24 Compliance.
Warranty: ELCO Lighting warrants products will be free from defects in materials and workmanship for a
period of 3 years.
Dimensions
Product Numbers
Item Lamp type Watts Voltage
EL5IC100A Medium Base (E26) 100W 120V