KEYBOARD KLAVIATŪRA EKB3 INSTALLATION MANUAL
EKB3 is a keyboard intended to use with GSM alarm and management system ESIM264. Main EKB3 keyboard functions are: • arm and disarm security system • arm and disarm STAY mode • configure system parameters • display information with LED indicators • inform about system status via sound signaler The keyboard uses two password levels - user and administrator. System configuration can be performed by entering administrator password and using programing commands.
1. Package content 1. EKB3 keyboard........................ qty. 1 2. User manual............................. qty. 1 3. 5,6kΩ resistor........................... qty. 1 2. Device installation 1. Detach Keyboard holder from EKB3 keyboard and fix it to the wall. Keyboard holder detach points are marked with rows (see Fig. No. 1). DOWN SIDE BACK SIDE Fig. No. 1 2. Disconnect security system ESIM264 power supply and backup battery before connecting the wires. 3. Connect keyboard connectors to ESIM264.
3.2 LED indicator functionality ARMED Armed security status indicator READY Indicates when all zones are inactive SYSTEM Administrator mode activation indicator ACK SIDE BYPS Temporary zone disconnection status indicator 1-12 Indicates violated zones 3.
4. Operation description When the system is disarmed and operating normally it will display green LED called READY. When any zone is violated, the green LED called READY turns off and the red LED with the number of violated zone shows up. System sound signaler uses two type of signals - three short beeps and one long beep. Three short beeps stands for successful complete tasks and one long beep stands for unsuccessful complete tasks. Star (*) button stands for cancel. 4.
4.3.1 Users commands Allow Only Preset Users When this function is enabled, the system reacts to the SMS messages-commands that are sent only from registered telephone numbers. If this function is disabled, the device can be controlled by all users who know the number of the SIM card inserted in the device, control commands and the main password. Factory default setting – enabled.
Disable Call during Alarm A function disabling calls to the specified users in the case of an alarm. By default, this function is disabled. EKB3 Disable SMS during Alarm Enter code 31 and function: Disabled – [310#] Enabled - [311#] Indicates partition in which user is assigned. EKB3 USER MANUAL EKB3 V1.0 Disabled – [300#] Enabled - [301#] A function disabling SMS message delivery to the specified users in the case of alarm. By default, this function is disabled.
iButton Partition Indicates partition in which iButton key is assigned. EKB3 Enter code 60, iButton number and partition: iButton 1 – [6001x#] iButton 2 – [6002x#] iButton 3 – [6003x#] iButton 4 – [6004x#] iButton 5 – [6005x#] where x – 0: partition 0, 1: partition 1. 4.3.2 Password commands SMS Password The main 4 digit SMS password which is used for system configurations and control via SMS messages. By default, password is 0000, which is NECESSARY to change.
Change Keyboard Password This function changes entered keyboard password with new one. EKB3 Enter code 63, old keyboard password and new keyboard password: [63xxxxyyyy#] where xxxx – old keyboard password, yyyy - new keyboard password. Add Keyboard Password This function adds new keyboard password. EKB3 Delete Keyboard Password Enter code 65 and keyboard password: [65xxxx#] where xxxx – keyboard password.
4.3.3 Zones commands ATZ Mode When ATZ mode (zone duplication) is enabled, the zone number is increased to 12. By default, ATZ mode is disabled. EKB3 Arm-Disarm By Zone Disabled – [280#] Enabled - [281#] Choose the zone which will work in Arm-Disarm mode. With this zone security system can be activated/deactivated with a “low” level impulse which is not shorter than 3 seconds. This mode can be set only for one zone.
Zone Mode ATZ In the environment of ESIM264 Configuration Tool the user must specify the mode of connected Zones: • Type4 – 5,6KΩ end of line resistor and normally closed contact with 3,3KΩ end of line resistor and normally closed contact. This type of connection is used for ATZ mode. • Type5 – Tamper and 5,6KΩ end of line resistor and 5,6KΩ end of line resistor with normally closed contact and 3,3KΩ end of line resistor with normally closed contact. This type of connection is used for ATZ mode.
Zone Type Follow – this zone doesn't react to violations during Delay time. Instant - when this zone is violated, immediately cause an alarm. Delay - doesn't react to violations in time period which is used to enter security password. 24H - this zone is active all the time, even when the system is disarmed. Fire - this type of zone is used to connect smoke detectors. Silent - this zone works as 24H zone and when it is violated, the system doesn't turn on the siren.
STAY STAY mode enables the users to arm and disarm security while staying inside the secured premises. The zones which are configured as STAY, will not be secured if the person does not leave the premises after activating security system. By default, this function is disabled. EKB3 Zone Partition Zone 1 – [5601x#] Zone 2 – [5602x#] Zone 3 – [5603x#] ... Zone 44 – [5644x#] where x – 0: disabled, 1: enabled. Indicates partition in which zone operates. EKB3 USER MANUAL EKB3 V1.
4.3.4 Monitoring station commands CID Enable When this function is enabled, the system generates CONTACT ID messages and delivers them to monitoring stations. When this function is disabled, the system operates in normal mode, i. e., delivers messages only to registered users (other configurations in MS Settings section becomes inactive). EKB3 CID Messages Enter code 23 and function: Disabled – [230#] Enabled - [231#] Configure which Contact ID messages will be delivered to monitoring station.
User Messages When CID Enabled Configure which events SMS messages will be delivered to users when monitoring station function is enabled. By default, all these messages are inactive. Alarm Event – the messages about alarm events. Disarmed Event – the messages about disarm events. Armed Event – the messages about arm events. External Power Loss Event – the messages about external power supply loss events. External Power Restore Event – the messages about external power supply restore events.
Account A device access number which is used by the Monitoring station to determine the monitoring object. Initial account number (9999) must be changed. EKB3 Attempts Enter code 37 and number of attempts: [37xx#] where xx – number of attempts. IP address of the router that the server is connected to. EKB3 16 [27xxxx#] where xxxx – account number.
DNS1 Primary DNS server IP address. EKB3 DNS2 Enter code 42 and DNS2 IP address numbers: {42xxxxxxxxxxxx#] where xxxxxxxxxxxx – DNS2 IP address numbers, e.g. 001010100254 for IP: 1.10.100.254 System can work via TCP or UDP protocol. EKB3 USER MANUAL EKB3 V1.0 {41xxxxxxxxxxxx#] where xxxxxxxxxxxx – DNS1 IP address numbers, e.g. 001010100254 for IP: 1.10.100.254 Primary DNS server IP address.
Server Port Router port number used for communicating with the device. EKB3 Local Port [45x] where x – port number. Enter code 46 and test period: [46x#] where x – test period. Identification number of device, which receives CONTACT ID protocol messages via GPRS. This parameter is only useful when security system works with EGR100 software. EKB3 18 Enter code 45 and port number: Period time of sending CONTACT ID protocol messages to monitoring station.
Communication Type Communication type which is used to transfer CONTACT ID protocol and can be set to operate via voice calls (GSM audio channel) or GPRS network. EKB3 Enter code 48 and select communication type: GPRS Network – [480#] Voice Calls - [481#] 4.3.5 Temperature commands ATTENTION: If you don‘t want to receive messages about temperature changes - temperature Min and Max parameters must be set zeros.
Temperature Limit Info SMS When this function is enabled, system sends the information by SMS messages about temperature deviation from the set values. By default, this function is enabled. EKB3 Enter code 50 and function: Disabled – [500#] Enabled - [501#] 4.3.6 Other commands Alarm time This parameter is used for setting the time of device alarm siren sound after the alarm is activated. The time is indicated in minutes. Factory default setting – 1 minute. Parameter range from 00 to 10.
Check External Power Status When this function is enabled the system informs users by SMS message about external power cut-off and restore. Factory default setting – enabled. EKB3 Users Enter code 17, user number and phone number: [17xxyyyyyyyyyyy#] where xx – user number, yyyyyyyyyyy – user phone number. Enable this function if you want to register iButton keys to the system. After registering iButton keys, this function must be disabled. EKB3 USER MANUAL EKB3 V1.
Bell Squawk Enable A short siren informs about enabled/disabled security system. EKB3 Chime Enable Enter code 32 and function: Disabled – [320#] Enabled - [321#] Enable this function when module EPGM8 is used. The number of outputs will be increased to 12 units. EKB3 22 Disabled – [290#] Enabled - [291#] When this function is enabled, users will be informed with sound signal of the keyboard speaker about any triggered Delay zone sensors even when the system security is not activated.
Language ESIM264 communicates with on of these languages: Lithuanian, Russian, English, Estonian, Latvian, German or Slovakian. EKB3 Log Enable Enter code 36 and function: Disabled – [360#] Enabled - [361#] This function enables and disables automatic output control. Specific automatic output control configuration can be done only with software “ELDES Configuration Tool”. EKB3 USER MANUAL EKB3 V1.
Keyboard Partition Indicates partition in which operates the keyboard. EKB3 Reset To Default Enter code 62 and administrator password: [62xxxx#] where xxxx – administrator password. This function enables to change date and time settings. EKB3 24 Keyboard 1 – [5101x#] Keyboard 2 – [5102x#] Keyboard 3 – [5103x#] Keyboard 4 – [5104x#] where x – 0: partition 0, 1: partition 1. This function resets all device parameters to default values.
5. Additional Information Limited Liability The buyer must agree that the system will reduce the risk of fire, theft, burglary or other dangers but does not guarantee against such events. “ELDES UAB” will not take any responsibility regarding personal or property or revenue loss while using the system. “ELDES UAB” liability according to local laws does not exceed value of the purchased system.
Made in Lithuania. Pagaminta Lietuvoje. www.eldes.