User manual

38
38 EN
EPIR2 User Manual v.1.4
System Status Information
Function Command Value Range / Comment Example
Set the periodic
system status
SMS/text mes-
sage
XXXX_IN-
FO:FF.TT
FF = frequency in days, [01... 10]; TT =
time, [01... 23]
By default, this status SMS/text mes-
sage will be sent daily at 11:00am.
1111_INFO:02.10
This status SMS/
text message will
be sent every 2nd
day at 10:00am.
Disable periodic
system status
SMS/text message
XXXX_
INFO:00.00
1111_INFO:00.00
Alarm Notication Settings
Function Command Value Range / Comment Example
Disable ring from
the system in case
of alarm
XXXX_CALLS:OFF By default the system makes a
phone call to the User 1 number
in the event of an alarm. You
may wish to congure the sys-
tem so that a phone call is NOT
made when an alarm occurs
(you may prefer to receive only
SMS notications).
1111_CALLS:OFF
Enable ring from
the system in case
of alarm
XXXX_CALLS:ON 1111_CALLS:ON
Disable SMS/text
message from the
system in case of
alarm
XXXX_SMS:OFF The system sends an SMS/text
message to the User 1 number
in the event of an alarm. You
may wish to congure the
system to cease sending these
messages when alarm occurs.
1111_SMS:OFF
Enable SMS/text
message from the
system in case of
alarm
XXXX_SMS:ON 1111_SMS:ON
NOTE: The underscore symbol ‘_’ in these instructions represents a space. So when typing an
SMS/text message, replace the underscore symbol with a single space.